Laserfiche WebLink
• • <br /> Geologita[Tecknicslitc. Page 4 <br /> Geoprobe Investigation <br /> Project No. 425.2 <br /> September 18,2008 <br /> Sample W4.35xlOE-6 <br /> BSS-2 @ 18' <br /> BSS-2 @ 20' <br /> BSS-2 @ 28' 7 <br /> BSS-2 @ 30' 6 <br /> 1.4 Contaminant Distribution <br /> The soil and groundwater mass balance calculations were presented in GTI's "Soil <br /> Excavation Report" dated January 28, 2002. In summary - approximately 11,632 lbs. of <br /> TPH-g was estimated in the calculations, and according to the excavation contaminant mass <br /> removal calculations, approximately 4,900 lbs. (42%) of TPH-gasoline was removed with <br /> soil excavation. Therefore, about 6,700 lbs. of TPH-g has not been removed. <br /> 1.5 Zone Divisions <br /> The aquifer is divided into four zones (Zones A through D) defined by the screen intervals of <br /> the sixteen monitoring wells associated with the site. (Table 1) <br /> • Zone A includes monitoring wells screened between 5 and 22-feet bgs <br /> (MWs: 1 —8) <br /> • Zone B includes monitoring wells screened between 32 and 35-feet bgs <br /> (MWs: 2X, 101, 105, 106, SW-101, SW-102) <br /> • Zone C includes monitoring wells screened between 45 to 49.5-feet bgs <br /> (MWs: 102, 107,201) <br /> • Zone D is represented by MW-202 screened between 79 and 81.5-feet bgs <br /> (MW-202) <br /> 2.0 PROPOSED INVESTIGATION <br /> In an attempt to better define the horizontal and vertical extent of plume migration on the <br /> north side of the site GTI proposes to install up to 15 direct push boreholes to a depth of 40 ft <br /> bgs (Figure 2) and test both soil at different depths and groundwater for gasoline based <br /> contaminants. By looking at the TPH-G plume shown in Figure 3 it can be seen that the <br /> contour generated using the Surfer Package can't be reliable since we don't have any data on <br /> the north side of the site between MW-2 and the two wells on the north side of Durham Ferry <br /> Road (MW-6 and MW-7). Figure 3 shows the distribution of TPH-G in the shallow zone <br /> (Zone A) while MW-6 and MW-7 have been non-detect for the whole site history and MW-2 <br /> has been the most contaminated well. The contours on the north side of the site are all the <br /> result of interpolation between these three points and can be questioned in the regard that <br /> MW-2 contamination plume might simply be an isolated pocket of contamination. To clarify <br /> this, a geo-probe investigation at the site is required. <br />