My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
15135
>
3500 - Local Oversight Program
>
PR0544644
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 11:56:52 PM
Creation date
7/10/2019 4:44:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0544644
PE
3529
FACILITY_ID
FA0005287
FACILITY_NAME
H & H MARINA
STREET_NUMBER
15135
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95219
APN
06908021
CURRENT_STATUS
02
SITE_LOCATION
15135 W EIGHT MILE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' WORK PLAN-Monitor Well Installation <br /> Herman&Helen's Marine <br /> May 30, 1997 <br /> ' Page-2- <br /> UST excavation at depths of 9 to 12 feet below the ground surface (bgs). The samples were analyzed <br /> for TPH-G (gasoline), BTEX, TEPH (diesel), EDB (ethylene dibromide), and total lead. Laboratory <br /> ' analyses indicated elevated concentrations of TPH-G, TEPH, and BTEX constituents in the soil <br /> samples. For additional information, refer to Tank Pull Testing Results, prepared by Condor, dated <br /> November 18, 1991. <br /> At the direction of the PHS/EHD, Condor prepared a work plan to investigate the gasoline and diesel <br /> contamination associated with the former USTs (Soil and Groundwater Investigation Work Plan, dated <br /> ' May 30, 1995). The work plan was approved by the PHS/EHD and the Reclamation District #2029. <br /> On August 22, 1995, three (3) hydropunch boreholes (HP-1, HP-2, and HP-3) were drilled at the site <br /> (Figure 2, Appendix A). Ronald Rowe of the PHS/EHD was on site periodically to observe the <br /> fieldwork. Gilbert Cosio of Murray, Bums, and Kienlen Engineering was on site to observe the <br /> drilling activities as a Reclamation District representative. Two (2) of the hydropunch boreholes (BP- <br /> I and HP-2) were located on the levee and were drilled to depths of approximately 16 and 11 feet <br /> below the top of the levee (btl), respectively. The third hydropunch borehole (HP-3) was located <br /> below the levee and was drilled to a depth of approximately 6 feet below the ground surface (bgs). <br /> Soil samples were collected at five (5) foot intervals. Groundwater samples were collected using a <br /> Hydropunch II groundwater sampler. Gasoline odors were noted in each borehole. Laboratory <br /> analyses indicated concentrations of TPH-G and BTEX in the soil and groundwater samples analyzed <br /> ' from each borehole (see Tables 2.1 and 2.2, below). <br /> ' TABLE 2.1 <br /> Laboratory Results (Soil - August 1995) <br /> B T E X TPH-G TEPH <br /> ' Detection 5.0 5.0 5.0 5.0 1.0 1.0-10 <br /> Sample I.D. Limits: µg/kg µg/kg µg/kg gg/kg mg/kg mg/kg <br /> 1432-HPI-11 (#) 1,200 3,100 5,500 22,000 300 190 (diesel) <br /> 1432-HP2-11 (#) ND ND 130 2,800 22 ND <br /> 1432-HP3-5.5 61 1 68 5.2 91 7.5 16 (diesel) <br /> Note:The last number in each sample ID indicates the depth at which the sample was collected. <br /> ' Unit Conversions: <br /> ltg/kg:parrs per billion(ppb) B,T,E,X =benzene,toluene,ethyl benzene,and total xylenes. <br /> mg/kg:parts per million(ppm) TPH-G=total petroleum hydrocarbons,quantified as gasoline. <br /> 1 TEPH =total extractable petroleum hydrocarbons,quantified as diesel, <br /> motor oil, and kerosene. <br /> ND=none detected at or above laboratory detection limits. <br /> #=detection limits raised due to gasoline interference. <br /> ' `� CONDOR <br />