Laserfiche WebLink
Note: Contaminants are anticipated in some, if not most, areas of subsurface work; should evidence of <br /> contamination become apparent, then protective gloves, including a latex liner and chemical resistant <br /> outer gloves and Tyvek-coverall will be required(see selection criteria below). In addition, latex over- <br /> boots(disposable)or reusable chemically resistant over-boots or steel toe over the sock rubber boots will <br /> be necessary. Provisions for decontamination must be established at any exclusion zone where non- <br /> disposable outer boots are to be wom. <br /> Connection between outer boots and suit, outer gloves and suit must be sealed <br /> with duct tape whenever polyethylene or saranex-coded coveralls are in use. <br /> For operations which require work gloves to protect the hands from abrasion, sharp <br /> edges, etc., leather(or equivalent) work gloves may be worn OVER chemical resistant <br /> gloves. Such gloves will be dedicated to exclusion zone work, but must be assumed <br /> i to be chemically contaminated once put into service. <br />' Upgrades of additional equipment may be mandated by the FSS based upon conditions <br /> or activities. Substitutions other than those described in this section are permissible <br /> only upon approval by the FSS. <br /> i' 8.2 Level C Protection <br /> Consists of the addition of the following respiratory protection to the Level D <br /> ensemble (Section 8.1): <br /> • Full face air purifying respirators with combination HEPA/organic vapor/acid <br /> cartridges. <br />' Eyeglass inserts MUST be provided for those employees who require <br /> prescription eyewear. <br /> 8.3 Criteria for upgrading to level C <br /> ' The presence of any one of the following conditions shall be sufficient to require <br /> Level C PPE. <br /> ' Verified detection of combustible gas levels in the breathing zone using the <br /> combustible gas meter. The detection of methane is likely to be an indication <br /> of the presence of other contaminants. <br /> • "Verified" organic vapor levels in the breathing zone, as measured by PID: <br /> ' > 2 ppm above background, sustained for five minutes. <br /> 215 ppm above background, sustained for one minute. <br /> • The detection of readings above background at the borehole/pit shall be noted <br /> in the sampling log as evidence of environmental contamination, but only <br /> ' CRC Environmental Misr Management,Inc. Project a4F2100-250-2 <br /> American Savings Bank 222 North BI Dorado Street <br /> April 6, 1995 16 Stockton,California <br /> i <br />