My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 1:58:23 PM
Creation date
7/12/2019 1:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
CHEROKEE LANE SERVICE STATION*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />CHEROKEE LANE SERVICE STATION' <br />Facility Address: <br />900 S CHEROKEE LN, LODI <br />Date: <br />October 28, 2014 <br />UST System Observations <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V ❑ R ❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />■ V ■ R ■ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R ❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V ❑ R ❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br /># <br />Remarks <br />rItem <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the February 2014 and <br />the September 2014 designated operator monthly inspection reports and failed to check that they were responded to <br />appropriately. The missing alarms include: diesel fuel alarm triggered during the 2/7/2014 re -inspection, and no alarm <br />record was attached to the September 2014 designated operator inspection report. During the monthly inspection, the <br />designated operator shall review the alarm history for the previous month, check that each alarm was documented and <br />responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms <br />to the monthly report. Ensure that designated operators performing monthly inspections at this facility are including all <br />of the required information on the reports. This is a Class II violation. <br />Received by (initial):. <br />LeW. M4.! <br />Inspector: <br />JEFFREY WONG, Senior REHS <br />Phone: <br />(209) 468-0335 <br />Date: <br />10/28/2014 <br />Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.