SWRCB, January 2002 <br />° <br />14, LGA IV [�: ' . .1 <br />Page of <br />nrT 1 a VIII <br />7. UNDER -DISPENSER C0N1'AINMEN'1' UDC '1'ES'1'1NC; <br />Test Method Developed By: UDC Manufacturer — Industry Standard X Profes*A"RWEIVI N <br />_i Other (Spec) N U <br />Test Method Used: i i Pressure Vacuum X Hydrostatic <br />Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution:.00? <br />UDC Manufacturer: <br />t'DC # 1&2 <br />Bravo <br />t DC # 3&4 <br />Bravo <br />LIDC # -,&6 <br />Bravo <br />t1DC # 7&8 <br />Bravo <br />UDC Material: <br />Coated Steel <br />Coated Steel <br />Coated Steel <br />Coated Steel <br />UDC Depth: <br />9" <br />9" <br />9" <br />9" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />Enters from bottom <br />Enters from bottom <br />Enters from bottom <br />Enters from bottom <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Enters from bottom <br />Enters from bottom <br />Enters from bottom <br />Enters from bottom <br />Condition of UDC prior to <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC Tested' <br />Water Level 8" <br />Water Level 8" <br />Water Level 8" <br />Water Level 8" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />No <br />No <br />No <br />No <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?* <br />Yes <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be <br />operational?* <br />No <br />No <br />No <br />No <br />Wait time between applying <br />water and starting test <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />11:00 <br />11:05 <br />10:40 <br />10:50 <br />Initial Reading (Ri): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />11:30 <br />11:35 <br />11:10 <br />11:20 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Chane in Reading (RF-Ri): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Pass <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced and <br />verified fimctional after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Com ments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to ay of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />