My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2019 10:37:47 AM
Creation date
7/30/2019 10:35:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J O A Q U I N Environmental Health Department <br /> / <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BlackHawk Petroleum Inc. 5611 E WATERLOO RD, STOCKTON July 29, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> 1) Financial responsibility documents have not been submitted to the EHD. The financial responsibility documents <br /> found on CERS expired on 4/25/2019. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> 2)An approved copy of the financial documents were not available for inspection. A copy of these documents shall <br /> be accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit is not current in CERS. <br /> -The California Department of Tax and Fee Administration(CDTFA, previously BOE) number listed on CERS <br /> (44038631)is closed. <br /> Any change of information must be updated in CERS within 30 days of the changes. This information was updated <br /> on CERS while the inspector was onsite. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD.The UDC leak sensor manufacturer and the <br /> model number was left blank on the monitoring plans for all tanks.The monitoring plan must be uploaded to the <br /> California Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes, and <br /> submit for review by the EHD. <br /> This is a minor violation. <br /> 106 CCR 2632(d)(2), 2634(e) Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. The response plan must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, upload the completed form, and <br /> submit for review by the EHD. Ensure a copy is available for inspection at any time. <br /> This is a minor violation. <br /> 124 CCR 2637.2(d&e), 2665(a&b)"Overfill Prevention Equipment Inspection Report Form"not submitted within 30 days <br /> of inspection. <br /> Overfill Prevention Equipment testing was performed on 10/16/2018 and a test report was submitted on 04/04/2019, <br /> 5 months late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner <br /> This is a minor violation. <br /> FA0002160 PR0231764 SC001 07/29/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.