My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2015 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2015 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:07:11 PM
Creation date
8/5/2019 10:44:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2016
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1399\PR0231435\2016 RETROFIT PLANS SR0074936 .PDF
QuestysFileName
2016 RETROFIT PLANS SR0074936
QuestysRecordDate
5/22/2017 9:16:03 PM
QuestysRecordID
3392977
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/ Servicing <br />Software Version Installed: 333.03 <br />Complete the following checklist: <br />VALGEIVEL <br />OCT 16 2015 <br />ENVIRONMENTAL <br />• Yes <br />r No* <br />Is the audible alarm operational? HFA:TH • <br />+ Yes <br />r No* <br />Is the visual alarm operational? <br />(- Yes <br />f No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />l: Yes <br />r No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with <br />heir. ro r o eration? <br />• Yes <br />r No* <br />If alarms are relayed to a remote monitoring station, Is all communications equipment (e.g. modem) operational? <br />N/A <br />r No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring <br />stem detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check7l <br />rN/A all that applySump/Trench Sensors; Dispenser Containment Sensors. <br />IrYes <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? Yes; 0 No <br />Yes <br />r No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill <br />r <br />prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If <br />N/A <br />o at what percent of tank capacity does the alarm trigger? % <br />r Yes* <br />r No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E below. <br />r Yes, <br />r No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />+i Product; r Water. If yes, describe causes in Section E below. <br />(� Yes <br />r No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />r Yes <br />r No* <br />is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these aeticiencies were or will De correcrea. <br />less than SOml of liquid pumped from both reg and sup fill sumps. <br />Monitoring System Certification Page 2 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.