My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2015 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2015 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:07:11 PM
Creation date
8/5/2019 10:44:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2016
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1399\PR0231435\2016 RETROFIT PLANS SR0074936 .PDF
QuestysFileName
2016 RETROFIT PLANS SR0074936
QuestysRecordDate
5/22/2017 9:16:03 PM
QuestysRecordID
3392977
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1- FACH.YlrV INFORMATION <br />Facility Name: 7 -ELEVEN # 19976, MKT 2368 Date of Testing: 10/7/2015 <br />Facility Address: 1399 N. MAIN ST. @ NORTHGATE, MANTECA, CA 95336 <br />Facility Contact: BEN Phone: 209-239- ' <br />1 11 <br />Date Local Agency Was Notified of Testing: <br />Name of Local Agency Inspector (if present during testing): andria nrT I A 2,111� <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: TANKNOLOGY INC. — NFfA'TH r1CG+gATlpCK1T <br />Technician Conducting Test: Jarrod Cooke <br />Credentialst : R CSLB Contractor ❑ ICC Service Tech. r_1 SWRCB Tank Tester r Other (Specify) <br />License Number(s): 743160 <br />txy91Pw:3,110;lDr0-1&31QUI l i0)9001CIRI <br />fest Method Used By: r Hydrostatic r Vacuum r Other <br />"Fest Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />Spill Box # Tank T4 RUL - <br />Fill 1- Direct - Grade level <br />in containment sump <br />Spill Box # Tank T5 PUL - <br />Fill 1 - Direct - Grade level <br />in containment sump <br />Spill Box # <br />Spill Box # <br />Bucket Installation Type: <br />Direct Bury <br />49 Contained in Sump <br />% Direct Bury <br />(I Contained in Sump <br />0 Direct Bury <br />4 Contained in Sump <br />Direct Bury <br />Q, Contained in Sump <br />Bucket Diameter: <br />14.00 <br />14.00 <br />Bucket Depth: <br />12.00 <br />12.50 <br />Wait time between applying <br />vacuum/water and start of test <br />5 min <br />5 min <br />min <br />min <br />Test Start Time (Tl): <br />09:04:00 <br />09:04:00 <br />Initial Reading (RI): <br />11.75 in. <br />12.00 in. <br />Test End Time(TF): <br />10:04:00 <br />10:04:00 <br />Final Reading (RF): <br />11.75 in. <br />12.00 in. <br />Test Duration(TF–TI): <br />1 hr <br />1 hr <br />Change in Reading (RF–RI): <br />0.00 in. <br />0.00 in. <br />Pass/Fail Threshold or Criteria: <br />+/-0.00 <br />+/-0.00 <br />- <br />+/- <br />Test Result: <br />Pass <br />Pass <br />Comments - (include information on repairs made prior to tesliug, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: CJS Date: 10/7/2015 <br />[State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. <br />WO: 2324217 <br />
The URL can be used to link to this page
Your browser does not support the video tag.