Laserfiche WebLink
MONITCVING SYSTEM CERTIWATION <br />CERTIFICATION /TEST DATE: February 10 , 2010 <br />Al. FACILITY A2. OWNER <br />Name 7 -Eleven Market #2368 / Store #19976 Name 7 -Eleven, Inc <br />Address 1399 N. Main Street, Manteca, CA 95336 Address P.O. Box 711, Dallas, TX 75221 <br />Phone # 209-239-3252 Phone # 805-523-2949 <br />Contact Jay Stemley Contact Jay Stemley <br />E. COMMENTS <br />C 2006 Walton Engineering, Inc. <br />D. RESULTS OF TESTING /SERVICING <br />Make /Model of Monitoring System: Veeder-Root TLS -350 <br />Software Version Installed: 327.04 <br />Complete the following checklist: <br />❑ Yes ElNo* Is the audible alarm operational? <br />El Yes ElNo* Is the visual alarm operational? <br />EJ Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br />El Yes ❑ No* Were all sensors Installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />El Yes ElNo* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modems) <br />El N/A operational? <br />❑ Yes ElNo* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />El N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) C Sump/Trench sensors; El Dispenser Containment Sensors. <br />❑ Yes ElNo* Did you confirm positive shut -down due to leaks and sensor failure/disconnection? <br />El Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />El NIA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? _ <br />El Yes * ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes * El No Was any liquid found inside any secondary containment systems designed as dry systems? <br />(Check all that apply) El Product; ❑Water. If yes, describe causes in Section E, below. <br />El Yes ❑ No* Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />❑ Yes ElNo* <br />Page 2 of 3 <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />Page 2 of 3 <br />