My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
2200 - Hazardous Waste Program
>
PR0514068
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2019 10:10:59 PM
Creation date
8/6/2019 12:00:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514068
PE
2227
FACILITY_ID
FA0009865
FACILITY_NAME
KIA COUNTRY
STREET_NUMBER
1515
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21619005
CURRENT_STATUS
01
SITE_LOCATION
1515 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Condition of nozzles, flanges, fittings at tank: <br /> Good condition. No evidence of damage, cracks, or leaks. <br /> Condition of piping: <br /> The piping is in sound condition and properly supported. <br /> Visual Inspection findings: A visual inspection of the tank and its affiliated <br /> pumps, piping and ancillary equipment did not reveal signs of leaks, corrosion, <br /> weld cracks or breaks, or scrapes in protective coating which may cause a <br /> Blease from the tank system. A description of all discrepancies noted during the <br /> visual inspection is included with this report. Initials: P--'L3 <br /> Seismic/Anchoring: <br /> Civil engineer wet stamped seismic/dynamic/hydrostatic load calculations <br /> provided as Attachment "C" <br /> eismic/Anchoring findings: The tank as designed and operated, and the <br /> containment area in which it is located are adequately anchored and are <br /> eismicall sound. Initials: 1L3 <br /> Leak Test: 191(g)(9)/192(k)(10) <br /> The waste oil storage tank and ancillary equipment were sealed <br /> and subjected to a slight positive pressure. A bubble test was <br /> performed on the tank connections and piping with no indication of <br /> leakage. The secondary containment space was completely empty. <br /> Integrity testing findings: Based on the above noted integrity test and the results <br /> obtained from that test, the tank has sufficient integrity for its intended use. <br /> Initials: K3 <br /> Tank Drawing: 191(g)(2)(E)/192(k)(2)(E)) <br /> Tank: See Attachment "A" <br /> Kia Country - Manteca 5 Title 22 Waste Oil Assessment <br />