2227
FACILITY_ID
FA0009865
FACILITY_NAME
KIA COUNTRY
STREET_NUMBER
1515
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21619005
CURRENT_STATUS
01
SITE_LOCATION
1515 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Waste Oil Storage System: See Attachment "B" <br /> Tank Dimensions (primary storage): <br /> 9'-11" wide x 3'-6" deep <br /> Tank Height: <br /> Overall: 2'-0" <br /> Tank Gross Capacity (Volume): 500 gallons <br /> Tank Working Capacity (Volume) 500 gallons <br /> Secondary Containment Assessment <br /> The secondary containment for the waste oil storage tank is provided by <br /> the HDPE liner of the external concrete tank. <br /> Volume Calculation 66264.193(e)(1)(A) <br /> The dimensions of the secondary containment are: <br /> 10'-0" wide x 3'-5" deep x 2'-0 1/2" tall <br /> The volume of secondary containment is 521 gallons <br /> Design of tank: 66264.193(e)(3) <br /> Design Standard: UL-42 <br /> The waste oil storage tank is of double wall construction, with the inner <br /> tank fabricated of welded 0.125" thick carbon steel as detailed in <br /> Attachment "A". No corrosion protection is provided for the inner surfaces <br /> and none is required due to the petroleum based contents. The secondary <br /> containment is provided by a 6"thick concrete shell lined with a 30 mil <br /> HDPE plastic membrane. External concrete corrosion protection is <br /> provided by a coating of epoxy paint. An audible high level alarm is <br /> installed. When tested during the inspection, it was in good working order. <br /> A daily documented inspection is performed which will detect any leaks <br /> within 24 hours per 22CCR66265.1920)(3). <br /> Kia Country - Manteca 6 Title 22 Waste Oil Assessment <br />