Monitoring System Certification <br /> D. Results of Testing/Servicing, <br /> Software Version Installed: 24.02 <br /> Complete the following checklist: <br /> ❑ Yes ❑ No* Is the audible alarm operational" <br /> E] Yes ❑ No* Is the visual alarm operational:' <br /> ® Yes ❑ No* Were all sensors visually inspected, functionally tested,and confirmed operational° <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondan containment and positioned so that other equipment will <br /> not interfere with their proper operation". <br /> ❑ Yes ❑ No* IF alarms are relayed to a remote monitoring station. is all communications equipment (e.g., modem) <br /> ® N;A operational" <br /> El Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ ti N monitoring system detects a leak. fails to operate. or is electrically disconnected`? If yes: which sensors initiate <br /> positive shut-down' tC'heck a!!Thal apphri ® Sump."Trench Sensors: ® Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure disconnection? ® Yes, ❑ No. <br /> ❑ l es ❑ No* For tank s\aems that utilize the monitoring system as the primary tank overfill warning device (i.e.. no <br /> ® N'A mechanical oertill prevention valve is installed). is the overfill warning alarm visible and audible at the tank <br /> till point(s)and operating properly? if so,at what percent of tank capacity does the alarm trigger" °,o <br /> ® Yes* ❑ No Was any monitoring equipment replaced' If yes, identify specific sensors, probes. or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E. below. <br /> ® Yes* ❑ No Was liquid t6und inside any secondary containment systems designed as dry systems'? IC'herk a//that ap[710 <br /> ❑ Product: ❑ Water. Ifyes.describe causes in Section E, below. <br /> i"Le <br /> ElNo* W'as monitoring system set-up reviewed to ensure proper settings" Attach set up reports, if applicable <br /> ® El Is all monitoring equipment operational per manufacturer's specifications'? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: 91 STP SUMP SENSOR WAS REPLACED WITH A 323 SENSOR. SMALL AMOUNT OF LIQUID <br /> FOUND IN 87 STP SUMP. SITE HAS DOUBLE WALLED SUMPS AND DISPENSERS USING VR-420 SENSORS. <br /> GAVE ALARM PRINTOUT TO INSPECTOR <br /> I'm"e 2 of 3 <br />