My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2019 1:12:33 PM
Creation date
8/21/2019 2:53:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Forn Aendum for Vacuum/Pressure Interstitial r 'ors LG 163-1,Enc.II <br /> j} <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of <br /> this form must be included with the Monitoring System Certification Form, which must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Vianufacturer: -VR Model:— TLS 350 System Type: ❑ Pressure; ®Vacuum <br /> Sensor ID <br /> Component(s)Monitored by this Sensor: —87 LINE <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: VAPOR LINE <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 91 LINE <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: VENT LINE <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fall <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; 0 Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; ❑ Fail Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br /> How was interstitial communication verified? <br /> Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; Q Visual Inspection; ® Other(Describe in Sec.J, below) <br /> Vacuum was restored to operating levels in all interstitial spaces: ®Yes ❑No(If no, describe in Sec.J, below) <br /> J. Comments: sensor communication verified by sensor going into alarm at the panel <br /> If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.