INSTALL 2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
INSTALL 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2019 8:33:37 AM
Creation date
8/21/2019 3:51:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2005
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information This is a certification of a new installation. <br /> Facility Name: Waterloo Shell Bldg.No.: <br /> Site Address: 4315 E.Waterloo Rd. City: Stockton Zip: 95215 <br /> Facility Contact Person: Bill Norby Contact Phone No.: 209 369-2252 <br /> Make/Model of Monitoring System: Veeder- Root TLS 350 Date of Testing/Servicing: 05 /18 /2005 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: Gasoline-87 Tank ID: Gasoline-91 <br /> In-Tank Gauging Probe. Model: 0847390-109 ■ In-Tank Gauging Probe. Model: 0847390-109 <br /> Annular Space or Vault Sensor. Model: 0794380-302 ■ Annular Space or Vault Sensor. Model: 0794380-302 <br /> Piping Sump/Trench Sensor(s). Model: 0794380-208 ■ Piping Sump/Trench Sensor(s). Model: 0794380-208 <br /> Fill Sump Sensor(s). Model: 0794380-208 ■ Fill Sump Sensor(s). Model: 0794380-208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ■ Electronic Line Leak Detector. Model: 84848o-oot ■Electronic Line Leak Detector. Model: 848480-001 <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment e and model in Section E on Page 2). ■Other(s eci� equipment type and model in Section E on Pae 2). <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment t}pe and model in Section E on Page 2). ❑Other(specify equipment e and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> Dispenser Containment Sensor(s). Model: 0794380-208 ■ Dispenser Containment Sensor(s). Model: 0794380-208 <br /> Shear Valve(s). ■ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> E Dispenser Containment Sensor(s). Model: 0794380-208 ■ Dispenser Containment Sensor(s). Model: 0794380-208 <br /> Shear Valve(s). 0 Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Ploat s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *Ifthe facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that is information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of gene ating such ports,I have also <br /> attached a copy of the report;(check all that apply): Q System set-up ❑X A a history re <br /> Technician Name(print): Bruce Stewart Signature: L <br /> Certification No.: 006-05-0810 License.No.: 617238 <br /> Testing Company Name: Walton Engineering,Inc. Phone No.:(__?l 6 ) 373-1152 <br /> Site Address: 3900 Commerce Drive,West Sacramento,CA 95691 Date of Testing/Servicing: 05 / 18 /2005 <br /> UN-036-1/4 Page 1 of 3 Rev.06/04/01 <br /> CUPA: Environmental Health Department WALTON <br /> 04'471JSVIC�7ti 6':vlM, 61'�'v. <br /> INSPECTOR: John J.Jackson <br /> www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.