Laserfiche WebLink
4-11-2001 12:07PM FROM P.1 <br />Date: April 11, 2001 -j <br />WRITTEN MONITORING PROCEDURES <br />UNDERGROUND STORAGE TANK MONITORING PROGRAM <br />This monitoring program must be kept at the UST location at all times. The information on this monitoring program are <br />conditions of the operating permit. Be permit holder must notify San Joaquin Courtv OES and Cyan Joaquin County Environmental <br />Health within 30 days of any changes to the monitoring procedures, unless required to obtain approval before making the change. <br />Required by Sections 2632(d) and 2641(h) CCR. <br />Facility Name Waterloo Shell <br />Facility Address_ 4315 Waterloo Road. Stockton <br />A. Describe the frequency of performing the monitoring: <br />Tank Continuous electronic monitoring and annual tank testing. The stem is .remote <br />monitored by Veeder Root daily and all alarms will -trigger an immediate notification to <br />Veeder Root, <br />Piping Continuous electronic monitoring Annually all product lines are tested <br />B. What methods and equipment, identified by name and model, will be used for performing <br />the monitoring: <br />Tank: Automatic tank l:ausing;_ Veeder Root -TLS -350 vemion 8473 & 8493. Simolicity <br />system with Continuous Statistical Leak Detection (CSLD) for the product tanks. Leak <br />Rate: Q.2 Sph <br />Piping: Veeder Root TLS -350 with PLLD series 8484, pressurized line leak detection and <br />positive shut down of the turbines. Leak rate of 0.2 gph. <br />C. Describe the location(s) where the monitoring will be performed (facility plot plan should <br />be attached): <br />The monitor is located in the 1 -OFFICE <br />D. List the name(s) and title(s) of the people responsible for performing the monitoring and/or <br />maintaining the equipment. <br />_William Norby // Dealer <br />Irma Salmeron ! Manner <br />E. Reporting Format for monitoring: <br />Tank: A written monitoringlog. <br />Piping: A written monitoring log and annual certification <br />F. Describe the preventative maintenance schedule for the monitoring equipment. Note: <br />Maintenance must be in accordance with the manufacturers' maintenance schedule <br />but not less than every 12 months. <br />The monitoring systems shall be certified annually in accordance with manufacturers <br />recommendations. System set u,,_p must be checked to verify that the 99% operating mode <br />option has been selected. <br />G. Describe the training necessary for the operation of UST system, including piping, and the <br />monitoring equipment: The operators receive initial training when the equipment is first <br />installed. Each person attending signs a training letter certifying they received training. <br />The station is provided a manual explaining the 2 alarms that become audible/visual. and <br />it telI� thern what their response to these Alarms should be. Refer to the stations Health & <br />Safety green binder, Emplovee Training Section, located at the cashier counter, for more <br />detailed information. <br />