My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE FILE 2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
595
>
3500 - Local Oversight Program
>
PR0544793
>
SITE INFORMATION AND CORRESPONDENCE FILE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:51 AM
Creation date
9/3/2019 1:19:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
FILE 2
RECORD_ID
PR0544793
PE
3528
FACILITY_ID
FA0006237
FACILITY_NAME
HONEST AUTO SALE AND REPAIR
STREET_NUMBER
595
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23337004
CURRENT_STATUS
02
SITE_LOCATION
595 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u u <br /> Wright <br /> Environmental <br /> Services, Inc. <br /> CVi2D707 East 11'"street,Suite 120 <br /> APF, ' 6 Tracy,CA 95376 ! b <br /> March 9,2006 ENVIR D1 it i r ;AL7H l� <br /> Project No. 4090-P PERMR7SERVICES <br /> Ms. Janice Brown <br /> c/o Cox&Cox <br /> 1593 Arrowhead Drive <br /> St.Helena, California 94574 <br /> Re: Cox & Cox, Quarterly Monitoring Well Sampling Report,First Quarter 2006 <br /> Site at 595 East 11th Street,Tracy,CA <br /> Dear Ms. Brown, <br /> (Wright) has prepared this quarterly monitoring well <br /> Wright Environmental Services, Inc. <br /> As you know, several phases work have been <br /> sampling report for the above referenced site. response a t <br /> performed at this site. This quarterly groundwater monitoring work is in for site ruarterl <br /> from the San Joaquin County Environmental Health Department (SJC/EHD) q y <br /> groundwater monitoring for the dissolved plume. <br /> 1.0 Monitoring Well Sampling Methods <br /> A sampling subcontractor sampled the site on January 30, 2006. The attached table(s) lists the <br /> level data. The contract sampler proceeded to purge well <br /> wells historic and current groundwater <br /> volumes of groundwater using a submersible electric purging pump or bailer (a volume <br /> calculation was done for each well following sounding measurements). Conductivity, and <br /> water temperature measurements were obtained between each well volume purge, and thessee were <br /> noted on the attached groundwater sampling information sheets. Once these readings stabilized <br /> after two consecutive purge volumes, aquifer water was assumed to be entering the well. When <br /> the well recovered to about 80% of the initial water level, the sample was collected. Purge <br /> water was stored on-site in drums. The well sampling information sheets are attached. <br /> Each groundwater sample was collected with a new disposable bailer. The groundwater sample <br /> was then poured with minimum cavitation into the appropriate, laboratory prepared sample <br /> containers leaving minimum headspace. The sample container was then immediately capped, <br /> labeled under chain-of-custody documentation and placed in a chilled ice chest for shipment to <br /> STLChromalab,Inc. in Pleasanton,California(a State Certified Testing Lab). <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.