My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012101
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
12080
>
2600 - Land Use Program
>
PA-1800318
>
SU0012101
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:38 AM
Creation date
9/4/2019 9:35:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012101
PE
2631
FACILITY_NAME
PA-1800318
STREET_NUMBER
12080
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220-
APN
01727012
ENTERED_DATE
12/11/2018 12:00:00 AM
SITE_LOCATION
12080 E ACAMPO RD
RECEIVED_DATE
1/14/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\A\ACAMPO\12080\PA-1800318\SU0012101\APPL.PDF \MIGRATIONS\A\ACAMPO\12080\PA-1800318\SU0012101\CDD OK.PDF \MIGRATIONS\A\ACAMPO\12080\PA-1800318\SU0012101\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8) At least one accessible route shall connect accessible buildings, accessible facilities, accessible <br /> elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 9) At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines, which are <br /> otherwise connected by a circulation path. §11 B-206-2.4 <br /> 10) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required for <br /> each phase of the project. These parking space(s) shall be located as close as possible to the <br /> primary entrance to the building. <br /> 11) Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 of <br /> the California Plumbing Code. <br /> 12) Pursuant to Section 422.4 of the California Plumbing Code, toilet facilities shall be accessible to <br /> employees at all times, should not be more that 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs.The plans shall indicate the location <br /> of the toilet facilities and the travel distance from work areas. <br /> 13) This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> requirements of the California Code of Regulations, Title 22, Division 2, Chapter 2.7 <br /> o) FIRE CODE REQUIREMENTS: The following California Fire Code (CFC) requirements will be <br /> applicable to the proposed project. The following conditions shall be addressed prior to submittal of a <br /> building permit application to the Building Inspection Division. <br /> 1) CFC 507 Fire Protection Water Supply—Fire flow and hydrants shall be provided for the proposed <br /> project by the use of: CFC Appendix B. <br /> 2) If Fire Protection Systems are required they shall be installed according to the CFC, Chapter 9 <br /> and the appropriate standards and guides adopted in Chapter 35 of the California Building Code <br /> and the California Electrical Code. <br /> 3) CFC, Section 503 Fire Apparatus Access Road — Shall be provided as required by this section. <br /> 503.1.2—A secondary access may be required. <br /> 4) CFC, Section 906 Portable Fire Extinguishers—Provide portable fire extinguishers as required by <br /> this section. <br /> 5) CFC, Section 506 Key Box-A Knox®Box shall be installed according to the local fire department's <br /> instructions. Make application for the key box at the fire district having jurisdiction of this project. If <br /> there is an electronically controlled access gate at this site a Knox® key switch will also be <br /> required. <br /> 6) CFC, Section 5001.3.3.1 Properties of Hazardous Materials — A complete list of hazardous <br /> materials used and or stored at this site shall be provided. <br /> 7) A complete review, at building permit submittal,will require compliance with applicable codes and <br /> ordinances. <br /> 8) CFC, Section 105 Permits: Operational Permit(s) may be required prior to occupancy. <br /> 2. DEPARTMENT OF PUBLIC WORKS: (Staff Contact: Awni Taha, [209] 468-3000, see memo dated <br /> February 13, 2019) <br /> 3. DEPARTMENT OF ENVIRONMENTAL HEALTH: (Staff Contact: Jeffrey Wong, [209] 468-0335, see <br /> memo dated June 19, 2019) <br /> PA-1800318 (SA) Conditions of Approval 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.