My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012101
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
12080
>
2600 - Land Use Program
>
PA-1800318
>
SU0012101
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:38 AM
Creation date
9/4/2019 9:35:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012101
PE
2631
FACILITY_NAME
PA-1800318
STREET_NUMBER
12080
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220-
APN
01727012
ENTERED_DATE
12/11/2018 12:00:00 AM
SITE_LOCATION
12080 E ACAMPO RD
RECEIVED_DATE
1/14/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\A\ACAMPO\12080\PA-1800318\SU0012101\APPL.PDF \MIGRATIONS\A\ACAMPO\12080\PA-1800318\SU0012101\CDD OK.PDF \MIGRATIONS\A\ACAMPO\12080\PA-1800318\SU0012101\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The mean high water level and the edge of the riparian habitat shall be shown on the Site Plan. <br /> The open space buffer required above shall be shown on the Site Plan with the following note: <br /> Pursuant to Section 9-1510.5 of the San Joaquin County Development Title,this area <br /> is designated as a natural open space for riparian habitat and waterway protection. <br /> No development other than water dependent uses shall be permitted in this space. <br /> n) BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division: <br /> 1) A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with The 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2) A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> 3) The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br /> shop drawings, structural plans and calculations, plumbing, electrical and mechanical drawings <br /> and energy report. <br /> 4) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading.All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 5) For each proposed new building, provide the following information on the plans: <br /> a. Description of proposed use <br /> b. Existing and proposed occupancy Groups <br /> c. Type of construction <br /> d. Sprinklers(Yes or No <br /> e. Number of stories <br /> f. Building height <br /> g. Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC <br /> j. Occupant load based on the CBC <br /> 6) If high piled combustible storage is to be used in a building, an automatic fire sprinkler system will <br /> be required. <br /> 7) Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading zones; <br /> public streets and sidewalks; and public transportation stops to the accessible building or facility <br /> entrance they serve.Where more than one route is provided, all routes must be accessible. §116- <br /> 206.2.1 <br /> PA-1800318 (SA) Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.