My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0046344
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ALCALA
>
243
>
2600 - Land Use Program
>
SR0046344
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:22:24 AM
Creation date
9/4/2019 10:47:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SR0046344
PE
4301
STREET_NUMBER
243
Direction
W
STREET_NAME
ALCALA
STREET_TYPE
AVE
City
MOUNTAIN HOUSE
Zip
95391
APN
25634009
ENTERED_DATE
4/12/2006 12:00:00 AM
SITE_LOCATION
243 W ALCALA AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\B\BYRON\18692\WELL PLN CK\SR0046344.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r, Once all the required well work is completed and all records are submitted,a Report of Well Abandonment(Form <br /> OG159)or Reabandonment(modified Form OG159)will be sent to you.This report states that all of the <br /> requirements have been fulfilled relative to plugging and abandoning or reabandoning the well, removing well <br /> equipment and junk,and filing well records. <br /> r <br /> In the event a well cannot be plugged to present-day standards or the equivalent,a modified Report of Well <br /> Abandonment or Reabandonment(Form OG159)will be prepared stating that the Division does not recommend <br /> that a building be constructed over the well without further consideration.On the Construction-Site Plan Review, <br /> further consideration may be satisfied with additional reabandonment requirements,and/or recommendation of <br /> mitigation measures(e.g.,vent system,impermeable membrane, passive collection system,etc.). On some <br /> occasions,the Division will recommend that no building be constructed over the well. <br /> n. A Division engineer may prepare a Construction-Site Plan Review(Form OG190),which may include requirements <br /> and recommendations regarding surface mitigation for natural gas and any active wells and facilities that will <br /> remain after the development is completed. <br /> When the review process is complete,the reviewing engineer may affix a Division certification or review stamp to <br /> all three copies of the Construction-Site Plan and all three copies of the Plan Review(Form OG190).One copy is <br /> sent to the local permitting agency,one copy is sent to the applicant,and the third copy is retained in the district <br /> office. <br /> The Construction-Site Plan Review may have an expiration date of one year from the date of the review at the <br /> discretion of the District Deputy or local permitting agency. <br /> If an applicant does not comply with the Division's reabandonment statute requirements,which may be modified at <br /> local jurisdiction direction,the District will notify the local permitting agency of the situation. <br /> Contaminated Soil Found at a Construction Site <br /> r <br /> The Division will notify the local permitting agency if contaminated soil is found at a project site. <br /> 1.When contaminated soil is discovered either by the applicant or a Division inspector,the phrase'Contaminated <br /> soil was found in proximity to the well"may be used as a comment on the Construction-Site Plan Review. <br /> 2.When contaminated soil is discovered after the Division has issued a Construction-Site Plan Review letter,a <br /> follow-up letter may be sent to the local permitting agency. <br /> r <br /> 3. If an unrecorded well is discovered during the construction process,the Division must be notified immediately. <br /> Plugging and abandonment or reabandonment requirements will be determined at that time. <br /> Water Wells <br /> When an oil-or natural-gas well has been converted to a water well, the following policies apply: <br /> A. If a well was drilled for the purpose of exploring for oil and natural gas, and penetrated any oil or gas zone,or <br /> penetrated the base of fresh water,that well is considered to fall under the requirements of PRC Section 3208.1 <br /> and should be treated as such during the Construction-Site Plan Review. <br /> Wells that were converted to water wells and subsequently abandoned by water-well abandonment methods <br /> should be plotted on the construction-site plan and tested for leakage, because they penetrated below the base of <br /> _ fresh water or into oil and gas zones. <br /> B.Wells drilled as known water wells do not fall under the requirements of PRC Section 3208.1 and are outside of <br /> Division jurisdiction.The reason they should be on the construction-site plan and listed on the plan review is to <br /> avoid confusing them with an oil or gas well in the event that they become a problem in the future. However,if a <br /> water well is in an area of known shallow gas,the Division may recommend a vent system for the well. <br /> Vent Systems and other Gas-Mitigation Measures <br /> s. <br /> r <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.