Laserfiche WebLink
r <br /> THE SAN JOAQUIN COMPANY INC. <br /> 1 120 HOLLYWOOD AVENUE,SUITE 3,OAKLAND,CALIFORNIA 94602 <br /> v� <br /> . �C3 <br /> San Joaquin County Public Health Services Pte` <br /> Environmental Health Division <br /> Third Floor <br /> 304 East Weber Avenue <br /> Stockton, CA 95202 <br /> Date:November 29, 2001 <br /> Attn.: Ms. Rebecca Setliff <br /> Your Reference: Site.Code 1392 <br /> SUBJECT: Work Plan for Extended Site Characterization: Navarra Property, <br /> 7500 Eleventh Street, Tracy,California 95376 <br /> Dear Ms. Setliff: <br /> Following our recent telephone conversations, I wish to confirm the following: <br /> We will extend the scope of work for the extended site characterization program that was <br /> described in our Work Plan for Extended Site Characterization at Former Fueling Station, 7500 <br /> West Eleventh Street, Tracy, California, which was submitted to your office for review on <br /> October 17, 2001,to include the following. <br /> TWO DISCRETELY-SCREENED WELLS AT LOCATION OF PROPOSED WELL MW-11 <br /> An additional well will be installed at the location of proposed well MW-I1 (which will be <br /> renumbered MW-12) that is described in the work plan. This will result in installation of a cluster <br /> of two new wells at that location. Well MW-12 will have a total depth of 23 ft. and will be <br /> screened in the interval between 7 and 22 ft. BGS. MW-12A will have a total depth of 36 ft. and <br /> will be screened over the interval 30 to 35 ft BGS. <br /> t LOCATION OF PROPOSED WELLS MW-9 AND MW-10 <br /> Subject to field adjustment, based on data gathered from the first push-probe boring and other <br /> wells installed as part of the extended site characterization program, Well MW-9 will be installed <br /> as shown on the work plan. If appropriate, a second well, MW-10, will be located further south <br /> on the east side of Chrisman Road, north of West 11 th Street at a point that might supplement <br /> Well MW-9 and possibly aid in the detection of any analytes of concern in groundwater that <br /> might be migrating in the direction of the water supply well at 23950 Chrisman Road. (Originally <br /> proposed Well MW-10 will be installed,but will be renumbered MW-11). <br /> The final locations of Wells 9 and 10 will be selected in the field by application of the methods <br /> recommended in the Unites States Environmental Protection Agency's guidance document <br /> Expedited Site Assessment Tools for Underground Storage Tank Sites—A Guide for Regulators, <br /> published in March 1997. <br /> TELEPHONE: OAKLAND, CALIFORNIA(51 O)336-91 1 8 TRACY, CALIFORNIA(209)832-2910 <br /> i <br />