KLEINFELDER <br /> accordance with SJCEHD criteria. Approximately 2 inches of fine gravel was placed at the <br /> bottom of each test hole. <br /> The percolation tests were presoaked with at least 12 inches of water on May 30, 2005. And <br /> the tests were initially performed on May 31, 2005, in accordance with accepted guidelines <br /> using clear potable water. The testing was done in warm and sunny conditions. The <br /> approximate depth of each percolation test below existing site grade is shown on the following <br /> table. The holes did not exhibit sloughing or caving. From a fixed reference point, a marked <br /> location on the side of PVC pipe inserted into each hole, the drop in water levels were <br /> measured in approximate 30-minute intervals for four hours, refilling as necessary to maintain <br /> the prescribed amount of water over the gravel (SJCEHD Procedure #2). As specified, the last <br /> two 30-minute readings were recorded under the observation of a representative from the <br /> SJCEHD and were used to calculate the percolation rate in minutes per inch. These initial <br /> shallow and deep test holes did not exhibit adequate percolation. Our drill rig returned to the <br /> site on June 3, 2005 and installed an additional deep percolation test hole in each lot using 6- <br /> inch diameter auger. The test holes were prepared as described above. The test holes were <br /> presoaked on June 5, 2005, with at least 12 inches of water. These percolation tests were <br /> performed under sunny and clear skies on June 6, 2005 in the same manner as described above. <br /> Details of each test can be found on the attached percolation test sheets. <br /> Depth of Test Hole Percolation Rate <br /> Lot Number Date of Test feet mindinch) <br /> 16 May 31, 2005 3.8 250.0 <br /> June 6, 2005 .2 25.0 <br /> May 31, 2005 3.4 125.0 <br /> 17 5.1 Did Not Percolate <br /> June 6, 2005 24.7 20.8 <br /> The results of our percolation tests indicate that a suitable soil percolation stratum exists at <br /> depths of approximately 24 to 25 feet below the existing ground surface. A suitable soil <br /> condition for tests deeper than 3% feet is defined as a stratum capable of percolating water at a <br /> rate of 30 min/inch or faster. <br /> Based on these results, conventional septic tank/leach trench sewage disposal systems designed <br /> per SJCEHD criteria should adequately serve the proposed residences constructed on these lots. <br /> Seepage pits should extend into the soil strata in which the passing percolation rates were <br /> obtained. <br /> Based on our results we do not anticipate a need for engineered systems to be installed at the <br /> residential parcels. <br /> 57556.G01/ST05R687 June 10,2005 <br /> ©2005 Kleinfelder,Inc. Page 4 of 5 <br />