Laserfiche WebLink
1 <br /> 3.7 Description of proposed or expected maximum (including second unit dwellings) septic <br /> ' tank usage on site: There are no immediate plans for construction. However, each parcel is entitled <br /> to a primary residence and a second unit dwelling. Any new septic systems must be constructed <br /> under a permit. <br /> ' 4.0 GROUNDWATER INFORMATION SECTION <br /> ' 4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br /> ground water in this area is approximately 40 feet according to the map of"Lines of Equal Depth <br /> to Groundwater" published Spring, 2016, by the San Joaquin County Flood and Water <br /> tConservation District. The gradient descends from east to west. <br /> 4.2 Description/discussion of any existing and/or potential groundwater <br /> ' contamination issues in the general location of the site: The concerns for groundwater <br /> contamination in this area are deemed moderate due to the depths involved. Insecticides, <br /> pesticides, and fertilizers typically do not significantly impact groundwater at these depths, <br /> ' however, as with any agricultural area, there is always a potential for contamination due to <br /> chemicals used in the farming operation. <br /> ' 4.3 Description of location (address/APN), type and construction of well and location <br /> (well head/kitchen tap)where water sample(s)were obtained: Water samples were taken from <br /> a spigot at the well located on the subject property, located at 20002 N. DeVries Road on <br /> December 13, 2017 by Matthew Murphy of Dillon& Murphy. <br /> 4.4. Description of constituents being tested for in the water sample: The water samples are <br /> ' being tested for nitrates and DBCP. <br /> 4.5 Description of how sample was obtained, handled, stored, and transported to the <br /> ' lab: The water samples were obtained from spigot located at 20002 N. DeVries Road. The <br /> samples were taken by Matthew Murphy of Dillon & Murphy, and driven directly to Precision <br /> Enviro-Tech. The samples were taken and handled in accordance with Precision Enviro-Tech <br /> ' requirements. The results from the test can be found in the Appendix. <br /> 4,6 Complete Chain of Custody document,including printed and signed name of third party <br /> ' sampler, condition of sample and date and time the sample was submitted to the lab. For <br /> Laboratory samplers, complete laboratory report to include the above noted information: <br /> The complete chain of custody document is located in the Appendix. <br /> ' <br /> 5.0 SOIL PROFILE INFORMATION SECTION <br /> ' 5.1 Site map showing the location, with dimensions, of the soil profiled pit on the parcel. See <br /> Appendix. <br /> 1 <br /> ' 2 <br />