My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011665
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELLIOTT
>
20703
>
2600 - Land Use Program
>
PA-1700268
>
SU0011665
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:19 AM
Creation date
9/4/2019 6:04:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011665
PE
2626
FACILITY_NAME
PA-1700268
STREET_NUMBER
20703
Direction
N
STREET_NAME
ELLIOTT
STREET_TYPE
RD
City
LOCKEFORD
Zip
95237-
APN
05121071, 72
ENTERED_DATE
2/12/2018 12:00:00 AM
SITE_LOCATION
20703 N ELLIOTT RD
RECEIVED_DATE
2/9/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\APPL.PDF \MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\CDD OK.PDF \MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\EH PERM.PDF \MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 9-1015.5[e]). The remaining driveways, maneuvering areas, and parking areas shall be <br /> surfaced with Class 2 Aggregate Base. <br /> 2) A minimum of forty-seven (47) parking spaces shall be provided at full buildout. (Development <br /> Title Section 9-1015.3) <br /> • Phase 1:A minimum of twenty-eight(28) parking spaces shall be provided. <br /> • Phase 2:A minimum of eight(8) parking spaces shall be provided. <br /> • Phase 3:A minimum of eight(8) parking spaces shall be provided. <br /> • Phase 4:A minimum of two(2) parking spaces shall be provided. <br /> • Phase 5:A minimum of one(1) parking space shall be provided. <br /> 3) Each parking stall shall be an unobstructed rectangle, minimum nine (9) feet wide and twenty <br /> (20)feet long. (Development Title Section 9-1015.5[b]) <br /> e) ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> 1) Access driveways shall have a width of no less than twenty-four(24) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty (20) feet wide. (Development Title Section 9- <br /> 1015.5[h][1]) <br /> f) LIGHTING: Lighting shall be provided and comply with the following: <br /> 1) If the parking area is to be used at night, parking lot lighting shall be installed. (Development <br /> Title Section 9-1015.5[g]) <br /> 2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that such <br /> light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> g) SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[9]) <br /> 2. BUILDING CODE REQUIREMENTS The following California Building Code (CBC) and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project. The following conditions shall <br /> be addressed prior to submittal of a building permit application to the Building Inspection Division: <br /> a) A building permit for each separate structure or building is required. Submit plans, Specifications, <br /> and supporting calculations, prepared by a Registered Design Professional (architect or engineer)for <br /> each structure or building, showing compliance with the 2016 California Building, Existing Building, <br /> Mechanical, Plumbing, Electrical, Energy and Fire Codes as may be applicable. Plans for the <br /> different buildings or structures may be combined into a single set of construction documents. <br /> b) A grading permit will be require for this project. Submit plans and grading calculations, including a <br /> statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br /> Professional. The grading plan shall show the existing grade and finished grade in contour intervals <br /> of sufficient clarity to indicate the nature and extent of the work and show in detail that it complies <br /> San Joaquin County PA-1700268/LA Delta Investments LLC <br /> Community Development Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.