Laserfiche WebLink
Due to a computer error, the continuing calibration for toxaphene was not analyzed. <br /> There were two injections of the individual component pesticide mix run and both were <br /> acceptable. After the error was discovered, the toxaphene standard was analyzed and <br /> was in control. The toxaphene continuing calibration was run within twelve hours. <br /> The MS/MSD associated with QC batch #1283161 was performed on an unrelated <br /> sample. The MS/MSD performed on sample D1J010146-003 is in control for all <br /> recoveries and RPDs. <br /> Phosphated Pesticides, SW846 8141A <br /> The method blank contained azinphos methyl, coumaphos, and dimethoate at <br /> concentrations greater than the reporting limit. The samples were re-extracted outside <br /> hold times. The method blank associated with the re-extraction had merphos detected <br /> at a concentration below the reporting limit, but greater than the method detection limit. <br /> The LCS associated with QC batch #1282272 demonstrated recoveries below the <br /> control limits for several compounds. The associated samples were re-extracted. The <br /> LCS associated with the re-extracted samples in QC batch 1291361 is in control. <br /> The MS/MSDs were all performed on an unrelated sample. <br /> The surrogate recoveries in samples DlJ010146-006 and 007 were outside the control <br /> limits. The samples were re-extracted and the recoveries are in control. The data from <br /> both analyses have been reported. <br /> Herbicides, SW846 Method 8151A <br /> In the analysis of sample DlJ010146-001 MCPP there was a difference greater than <br /> 40% between the primary and confirmation column results. The lower results are <br /> reported and the associated sample data are flagged "COL". <br /> The MS/MSD was performed on an unrelated sample. <br /> A continuing calibration verification (CCV) associated with samples D1J010146-002, <br /> 003, and 004 demonstrated percent differences greater than 15% for MCPP and <br /> dichlorprop. The average percent difference of all compounds in the CCV was less than <br /> 15%; therefore the CCV met all criteria for the method. <br /> 3 <br />