Laserfiche WebLink
w FROM:, FAX NO. :2099315186 . 06 2003 04:50PM P6 <br /> A. Environmenial Health De ment requires a Soi Sultab'I' /Nit to <br /> Lo In St d ISe t'c System Design— 1 hired Chesney Consulting of <br /> Turlock (upon your recommendation)on September 20, 2002 to perform <br /> this scope of work. Chesney Consulting completed his report dated <br /> December 31, 2002 and submitted the 65-page report to your office on <br /> January 22, 2003 along with the $445 required review fee. <br /> Don Chesney worked very closely with you during the preparation of his <br /> I report to insure that his design and analysis would meet your <br /> requirements. This is demonstrated by the inclusion In his report of <br /> numerous examples of where he has specified a feature or function "per <br /> EHD recommendations". In addition to the coordination by Chesney <br /> Consulting I have also discussed our project with you and Ray Borges <br /> many times throughout the approximately last two years in an attempt to <br /> understand and comply with your requirements. <br /> In addition to the conventional testing normally done for this type of <br /> project Chesney Consulting also performed additional testing to support <br /> his analysis including a double ring infiltrometer test. <br /> We have received no response from your office regarding this report. <br /> B. The applicant shall provide written_confirmation from the water oro�iders <br /> th@1 Improvements have been constructed or financial a an ements have <br /> een made for any Improvements required by the aciency and that the <br /> ency has or will have the capacity to serve the proposed development. <br /> As indicated on our site approval application, and on drawings submitted <br /> for permit purposes, our proposed facility in located within County Service <br />'F Area (CSA) 43, which provides drinking water to the township of <br />! Clements. <br /> I have requested a written will serve letter on three separate occasions at <br /> the Public Works Department Counter. Each time I have been told that <br /> our project is located within CSA 43 and no written will serve letter is <br /> required nor will be issued. <br /> Should you have any questions regarding the availability of drinkable <br /> water at our site please contact Dean Gilman, Public Works, at 468-3059 <br /> C. Submit t ee 3 sets of food facility fans to the Env' nmental Health <br /> Department for review and prior to issuance of bu'din a 't s <br /> (California Haalth and Safety Code, Section 113915), <br /> California Health and Safety Code, Section 113915 states, uA person <br /> proposing to build or remodel a food facility shall submit complete, easily <br /> readable plans, drawn to scale, and specifications to the local <br /> Page 2 <br />