As illustrated on the attached landscaping plan with the septic system overlay, the area reserved <br /> for the filter bed will actually accommodate a 40 feet x 45 feet= 1,800 square feet filter bed area. <br /> Standard Capacity Infiltrator® Chambers are specified with the following dimensions:34"x750tx12" <br /> Storage Volume= 78 gallons/chamber x 66 Chambers = 5,148 gallons temporary storage capacity <br /> CONFIGURATION OF PRESSURE DISTRIBUTION NETWORK <br /> The distribution of piping must discharge the effluent uniformly over the soil/effluent interface, <br /> with closely spaced orifices so that effluent application area is -6 f12/orifice. Force main piping <br /> will be a center-feed manifold to the laterals. There will be a total of 22 Iaterals - I 1 on each side <br /> of the manifold, six inches apart and three chambers per lateral. Orifices shall be drilled with a <br /> sharp drill and installed facing per manufacturer's recommendations. Clean-outs may be <br /> provided at the distal ends of the laterals per EHD recommendations. <br /> LATERAL LENGTH AND DIAMETER <br /> Piping to consist of PVC Schedule 40. Each lateral length to be -20 ft with a diameter of 2.0 in. I.D. <br /> PERFORATION SIZE, SPACING AND NUMBER PER LATERAL <br /> Perforations shall be 3/16 in. di a. For effluent distribution applications to be -6 ft'/orifice, the <br /> spacing of perforations= (area per orifice x no. of laterals on each side of center feed <br /> (absorption area width) = 6 ftZ x 2 - 3 ft=4 ft. The number of perforations per lateral shall be; <br /> N=(p—x) + 0.5 = (20 ft . 4 ft) + 0.5 = 5 perforations per lateral x 22 laterals = 132 perforations <br /> LATERAL DISCHARGE RATE (LDR) <br /> Recommended distal pressure is 3.5 ft for 3/16 in. orifices, translates to 0.78 gpm per orifice. LDR <br /> = 0.78 gpm/perforation x 5 perforations/lateral = 4 gpm/lateral <br /> MANIFOLD AND FORCE MAIN DIAMETER <br /> The force main and manifold may be 2.0 in. I.D., composed of PVC Schedule 40. <br /> NETWORK DISCHARGE RATE (NDR) <br /> NDR=22 laterals x 4 gpm/lateral = 88 gpm. <br /> FILTER BED DOSE VOLUME EXAMPLE <br /> A dose volume of-20% of design flow(1,500 gal/d ADF) may be used. Use 3 times the lateral <br /> void volume: <br /> Lateral dia. =2.0 in. <br /> Lateral length - 20 ft <br /> Number of laterals=22 <br /> Lateral void volume = 0.163 gal/ft <br /> Net Dose Volume = 3 x 20 x 22 x 0.163 =215 gals/dose <br /> Flow through force main and manifold = 77 ft at 0.163 gal/ft (2 inch I.D.) = 13 gal/dose <br /> Floats shall be set to dose an approximate volume total of 215 gals + 13 gals z 228gals/dose <br /> r <br /> 12 <br /> Chesney Consultin <br />