r <br /> KLEINFELDER <br /> An employee awned company <br /> File No. 29556.G01 <br /> December 8, 2003 <br /> Mr. Mike Jennings <br /> Lodi Grading and Paving <br /> P.O. Box 1301 <br /> Lodi, CA 95241-1301 <br /> Subject: ADDENDUM TO SOIL SUITABILITY STUDY <br /> 9167 EAST FIRST STREET <br /> VICTOR, CALIFORNIA <br /> Dear Mr. Jennings: <br /> Kleinfelder is pleased to present this addendum to our soil suitability study dated June 18, 2003 <br /> for the proposed septic systems at the commercial site located at 9167 E. First Street in Victor, <br /> California. This addendum has been prepared to address the comments by San Joaquin County <br /> Environmental Health Department (SJCEHD) in their letter September 16, 2003. <br /> • Items 1.4, 5.1, and 6.1 — The site plan is attached. Also attached is a parcel map <br /> from the SJCEHD Parcel Viewer program. <br /> • Item 2.1 — We understand that the site had previously been used as a recycling <br /> center. At the time of our investigation, the site had been vacated by the previous <br /> owners/business, No other information on prior uses of the site is readily available. <br /> • Item 3.1 — The on-site septic systems are currently not being used as the site was <br /> vacant at the time of our investigation. In addition, we understand that new septic <br /> systems are proposed to serve the existing buildings, which will be renovated, and <br /> the existing septic systems are to be abandoned. Details of the existing septic <br /> systems are unknown by Lodi Grading and Paving and no permits were on file with <br /> SJCEHD. Based on the lack of repair permits for this site and only one repair <br /> permit on file for any of the adjacent parcels, we assume that, in general, the <br /> existing septic systems in the project area are performing well. <br /> • Item 3.7 — We understand that the site will be used as a commercial facility for <br /> Lodi Grading and Paving. According to Mr. Greg Wright of WJ Development, a <br /> maximum of approximately 8 full-time employees are planned for the facility. It is <br /> unknown at this time which septic systems will serve which number of employees. <br /> Maximum septic wastewater flows of approximately 120 gallons/day are <br /> anticipated for the entire site (8 employees at 15 gallons/day/employee for sites <br /> without cafeteria facilities). Based on this, the septic tanks can be 1,200-gallon <br /> 29556.G01/ST03R1819 December 8,2003% <br /> ©2003 Kleinfelder,Inc. Page I of 2 <br /> KLEINFELDER 2825 East Myrtle Street,Stockton,CA 95205-4794 (209)948-1345 (209)948-0621 fax <br />