Laserfiche WebLink
KLEINFELDER <br /> tanks, according to SJCEHD criteria. The leach line requirement would be 264 <br /> linear feet ((1200+120)*0.200=264). For a filter bed, the required area is 792 <br /> square feet (264*3=792). <br /> • Item 5.3 —A copy of the boring log is attached. <br /> • Item 5.4 — In general, the moderately-permeable, near-surface sand and sandy silt <br /> in the project area yield percolation rates meeting SJCEHD percolation <br /> requirements. Based on the percolation test results and soil types encountered, we <br /> do not foresee the need for engineered or alternative septic systems. We do not <br /> anticipate any geotechnical restrictions on future type, size, or location of any <br /> additional leach fields/leach fields with seepage pits, as appropriate, for the subject <br /> project. <br /> • Item 6.1 — According to Mr. Wright, a lot line adjustment has been performed to <br /> include the land immediately south of the masonry wall in the same parcel as the <br /> rest of the site. This would mean the septic systems would be on the same parcel as <br /> the structures they serve. <br /> • Item 6.4 — The percolation test holes were still intact with no significant sloughing <br /> or caving noted. No standing water was present in the holes following the 24-hour <br /> soak period. <br /> The conclusions of this report are based on the information provided regarding the existing and <br /> proposed development and on the site conditions. It was assumed that the percolation test results <br /> are representative of the subsurface conditions in the general area. <br /> This completes the scope of work requested. Our work was performed in general accordance <br /> with the standard of care that exists in San Joaquin County. No other guarantee or warranty, <br /> expressed or implied, is made. <br /> Respectfully submitted, <br /> KLEINFELDER, INC. Reviewed by: t 3FESS/0*y <br /> // N `SF F� <br /> .2283 i z <br /> D(P.6-05 M <br /> Ronald E. Loutzenhiser, C.E. <br /> Staff Professional eote al Department A��coF <br /> REL:lr <br /> Attachments <br /> 29556.G01/ST03RI819 December 8,2003 <br /> ©2003 Kleinfelder,Inc. Page 2 of 2 <br />