Laserfiche WebLink
WASTE DISCHARGE REQUIREMENTS ORDER NO. 2 <br /> RICHARD A. STAGNO <br /> STAGNO'S MEAT COMPANY <br /> SAN JOAQUIN COUNTY <br /> the holding pens, to the treatment pond. A design flow of 30,000 gallons per day was used for <br /> sizing of the wastewater holding pond. <br /> 7. Wastewater from the slaughterhouse operations will be derived from one animal rinse, two <br /> carcass rinsings, and kill-floor rinsewater. A 2000 gallon septic tank and a screened, 2000- <br /> gallon grease trap will be used to treat wastes from the slaughterhouse operations prior to <br /> discharge to the treatment pond. Screenings and fats, oils, and greases (FOG) accumulated in <br /> the screened grease trap will be collected by the tallow operation. <br /> 8. The water quality of the slaughterhouse effluent was estimated based on a sample collected at <br /> another slaughterhouse that has no blood recovery and only gross solids removal, as reported <br /> below. Therefore, the effluent quality estimate should be conservative for the Discharger's <br /> facility. <br /> Concentration <br /> Compound In Milligrams per liter(me/1) <br /> Biochemical Oxygen Demand (BOD) 5501 - 1100 <br /> Suspended Solids 150 <br /> Total Kjeldahl Nitrogen 160 <br /> pH 8.0 (pH Units) <br /> 1 The BOD is estimated to be reduced by 50 percent by capturing 99 percent of all blood,screening of <br /> solids,and a grease trap. <br /> 9. The Discharger uses cleaning solutions consisting of a detergent concentrate/disinfectant. <br /> Approximately 16 gallons of the concentrated material will be used weekly, and will be diluted <br /> prior to usage. The cleaning solutions will be further diluted (6250 to 1), as they will be <br /> discharged with the process wastewater. <br /> 10. The treatment pond will be approximately 165 by 165 by 8 feet deep, and the base of the pond <br /> will be 4 feet below grade. The pond berms will be constructed using native soil and will be <br /> lined with 30-mil high density polyethylene plastic (HDPE). Fencing and warning signs will be <br /> placed around the pond. The influent lines are proposed for installation at the northern end of <br /> the pond while the effluent line will be placed at the southern end. <br /> 11. The Discharger proposes to triple crop sudangrass in the designated disposal area. Wastewater <br /> from the storage pond will be periodically applied to provide the Nitrogen requirement for the <br /> crop. A baseline soil sample of the cropland was analyzed in December 1997. The reported <br /> concentrations of Nitrogen (as Nitrate), Phosphorus, and Potassium are 8, 33, and 75 <br /> milligrams per kilogram, respectively. Soluble salts are reported to be 3.3 millimhos per <br /> centimeter. <br /> c:tckwf"i les\agriculturetagwdrs\stagno\stagnowdrs <br />