My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009662_SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
4 (STATE ROUTE 4)
>
24226
>
2600 - Land Use Program
>
PA-1300087
>
SU0009662_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:08:29 AM
Creation date
9/4/2019 6:45:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0009662
PE
2622
FACILITY_NAME
PA-1300087
STREET_NUMBER
24226
Direction
E
STREET_NAME
STATE ROUTE 4
STREET_TYPE
RD
City
FARMINGTON
Zip
95230-
APN
18711020
ENTERED_DATE
6/12/2013 12:00:00 AM
SITE_LOCATION
24226 E HWY 4 RD
RECEIVED_DATE
6/12/2013 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\HWY 4\24226\PA-1300087\SU0009662\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1 (Parcel 1) Satisfactory <br /> 7118/13 3.28 41.7 4 hr. <br /> Shallow Test pert. rate <br /> P2 (Parcel 2) <br /> 7/18/13 3.18 62.5 4 hr. Test failed* <br /> Shallow Test <br /> P2 (Parcel 2) Satisfactory <br /> 7/18/13 7.85 9.6 4 hr. perc. rate <br /> Deep Test <br /> Note. A satisfactory percolation rate for a "shallow" test is less than or equal to 60 minutes per inch. A satisfactory <br /> percolation rate for a "deep"test is less than or equal to 30 minutes per inch. <br /> Only a shallow or a deep test is required to pass for the lot to pass. <br /> Discussion of Percolation Test Results <br /> The soils within the percolation test area have demonstrated a satisfactory percolation <br /> rate for the use of a standard septic system in accordance with the requirements of the <br /> San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and seepage pits should follow the San <br /> Joaquin County On-Site Wastewater Disposal Standards (2003) where applicable. <br /> LOGE 1307 Page 7 <br />