Laserfiche WebLink
Y <br /> o <br /> t <br /> i <br /> Ii <br /> l <br /> E <br /> Soil Suitability Study APN: 209-150-16 UP-96-6 <br />'E so near the ground surface is because the test hole was excavated <br /> in the winter season and immediately after some recent rains which <br /> is when the water table would be at its highest level during the <br />€ year . <br /> E <br />[ Percolation Tests : A shallow percolation test was conducted and <br /> F performed in accordance with the percolation test procedures <br /> outlined in the "Manual Of Septic Tank. Practice" , published by the <br /> Department Of health, Education And Welfare and the requirements of <br /> the San Joaquin County Public Health Service, Environmental Health <br /> Division. <br /> A shallow Percolation Test Hole, No. PH was excavated to a <br /> depth of 35" . Then 2" of rock was placed in the bottom of the test <br /> hole and presoaked over--night . Since no water remained in the <br /> percolation test hole after the over-night soaking process , the <br /> drop in water level was then measured at 30 minute intervals for 4 <br /> hours, and the reading in the last 30 minutes resulted in a <br /> percolation rate of 120 minutes per inch for the subject <br /> property. Under drier test conditions the percolation rate could <br /> well have conformed to the County' s minimum standard of 60 minutes <br /> per inch since the standard was maintained for 3 1/2 hours and only <br /> -illedtconfaori"�tlie las�t1�%2jhour . The test was performed <br /> under v' '-satif ated con`d ti'o�ns c ated by recent rainstorms and <br /> rainfall occurring on the very day of the percolation rate <br /> determination. The result of the percolation test is summarized and <br /> tabulated as follows : <br /> TEST RESULTS : <br /> Test Hole Percolation Rate Minimum Usable Mound or <br /> NO . CMinutes Per Inch) Disposal Area EngineerDesigned <br /> _-- System <br /> PH (35" ) 120 (Failed) Yes <br /> Well Water Analysis : The property owner is making arrangements with <br /> others to test the well water on the subject property; so no well <br /> water analysis is contained in this study report and the results of <br /> the well water testing will be reported in other documentation <br /> separate from this study report . <br /> RECOMMENDATIONS : Due to the nearness of the ground water to the <br /> natural ground surface (7 ' 06" maximum and 6 ' 04 inches minimum) , as <br /> well as the percolation test not conforming to the San Joaquin <br /> County Standard _mi.ni.mum pe-r-col-at.:i-on rate -of 60 minutes per inch <br /> the use of a leh field or seepage pits is not acceptable.: Instead <br /> any future development of this property involving"' theineed of a <br /> septic system, a mound septic system design or a specially engineer <br /> Gurudawara Gur Nanak Parkash, 16101 West Gantline Road, Tracy, Ca. 4 <br /> i <br />