My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006293 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HANSEN
>
26955
>
2600 - Land Use Program
>
PA-0600514
>
SU0006293 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:32:16 AM
Creation date
9/5/2019 10:56:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0006293
PE
2632
FACILITY_NAME
PA-0600514
STREET_NUMBER
26955
Direction
S
STREET_NAME
HANSEN
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20911009
ENTERED_DATE
10/3/2006 12:00:00 AM
SITE_LOCATION
26955 S HANSEN RD
RECEIVED_DATE
10/3/2006 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HANSEN\26955\PA-0600514\SU0006293\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> ►. April 13,2007 <br /> NOA Project Number: E07046A <br /> 6.4 Condition of Borings After Presaturation <br /> After the 24-hour soak period,the presaturated holes were found to be intact and dry on the day of <br /> ., testing. <br /> 6.5 Percolation Test Procedure <br /> The percolation tests for the site were performed on April 9,2007.The test had a duration of foto j <br /> hours and was performed in accordance with the requirements of the EHD. The final half-hour of <br /> r, the test was observed by Ms. Lisa Medina,Senior Registered Environmental Health Inspector, <br /> EHD. <br /> Measurement of the water level during the percolation test was from a fixed reference point on the / <br /> PVC casing using an electric well sounder with an depth accuracy of 1/100th foot. All tabulated f <br /> values on the field data sheet (appendix) are in decimal feet. After water drop was observed, the <br /> holes were checked for refill. The refill level was approximately 0.5 ft (6 inches) of water above the <br /> bottom level of the percolation test hole. The readings were taken approximately every 30 minutes <br /> for a period of four hours. <br /> 6.6 Percolation Test Forms and Results <br /> .. The completed percolation test form is included in the appendix of this report. <br /> A shallow percolation test is defined by the EHD as being between 36 and 42 inches in depth;a / <br /> ` satisfactory percolation rate for a shallow test is less than or equal to 60 minutes per inch drop.A 6 <br /> satisfactory percolation rate for a deep test is less than or equal to 30 minutes per inch drop. Details <br /> of the percolation tests are summarized in Table 5. <br /> r <br /> Table 5. <br /> Summary of Percolation Test. <br /> Test No., Percolation Percolation Rate Test Comment <br /> Date Tested Test Depth(ft) (minutes/inch) Duration (see notes) <br /> Shallow 3.3 15.63 4 hr. Satisfactory Percolation Rate <br /> -07 <br /> Deep 12.5 50 4 hr. Failing Percolation Rate <br /> 4-9-07 <br /> Note: A satisfactory percolation rate for a"shallow'testis less than or equal to 60 minutes per inch. <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.