My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006921
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
30703
>
2600 - Land Use Program
>
PA-0800005
>
SU0006921
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:32:48 AM
Creation date
9/6/2019 9:55:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006921
PE
2627
FACILITY_NAME
PA-0800005
STREET_NUMBER
30703
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
APN
25313019 26
ENTERED_DATE
1/24/2008 12:00:00 AM
SITE_LOCATION
30703 S MACARTHUR DR
RECEIVED_DATE
1/11/2008 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MACARTHUR\30703\PA-0800005\SU0006921\APPL.PDF \MIGRATIONS\M\MACARTHUR\30703\PA-0800005\SU0006921\CDD OK.PDF \MIGRATIONS\M\MACARTHUR\30703\PA-0800005\SU0006921\EH COND.PDF \MIGRATIONS\M\MACARTHUR\30703\PA-0800005\SU0006921\EH PERM.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
730
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f) The project sponsor shall abide by the applicable Airport Land Use Plan for Tracy Municipal <br /> Airport and the Federal Airport Administration Advisory Circular No: 150/5200-33B, Hazardous <br /> Wildlife Attractants On or Near Airports. <br /> 6) CITY OF TRACY— BUILDING DEPARTMENT(Staff Contact: Kevin Jorgensen, (209)831-6415) <br /> a) The inside turning radius for fire access roads should be a minimum of 27'-7. <br /> b) Provide a water source in terms of hydrants or tanks appropriately sized for fire-fighting <br /> operations. <br /> c) No Smoking signage is required. <br /> d) Secure the appropriate operational fire permits for a) combustible dust producing facilities if the <br /> C&D fines qualify as combustible dust b) combustible fibers c) private fire hydrants if used d) <br /> miscellaneous combustible storage e) waste handling and f)wood products. <br /> e) For outdoor storage only noncombustible materials can be stored under high-voltage <br /> transmission lines. <br /> f) If there is combustible dust production, then the NFPA 664 standards will apply. <br /> g) Demonstrate on an expanded site plan where access roads begin and end. Figure A2 <br /> demonstrates a partial idea of such access. <br /> h) Where and what is the fuel source for the required material handling equipment? This will need <br /> to be demonstrated. <br /> i) Submit an emergency plan for monitoring, controlling and extinguishing spot fires for review <br /> and approval. <br /> j) Provide portable fire extinguishers rated 4A;60B;C on all vehicles and equipment. <br /> 7) SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT(Staff Contact: Mark Montelongo, <br /> (559)230-5905) <br /> a) The Districts Guidelines for Assessing and Mitigating Air Quality Impacts (GAMAQI) does not <br /> specifically identify a threshold of significance for PM10 emissions. However, the District <br /> recommends use of a 15 tons per year threshold as set by the New Source Review(NSR) Offset <br /> Requirements. Therefore the District recommends amending the MND and emissions <br /> assessments to reflect a 15 tons per year threshold of significance for PM10. Thresholds of <br /> significance for Reactive Organic Gas (ROG) and Oxides of Nitrogen (NOx) are also set in <br /> accordance with the NSR Offset Requirements. <br /> b) Currently the District is in the preliminary stages of developing a new draft rule (Draft Rule 4566) <br /> for Composting and Related Operations. The MRF/TS Compost Emission Estimates <br /> assessment/methodology may need to be revised based on the outcome of the rule development <br /> process. <br /> c) The project includes an expansion of 29,400 square feet to an existing 47,200 square foot <br /> building, and an additional 10,500 square foot expansion to an existing <br /> maintenance/administration building. The MND doesn't quantify or characterize the expansions <br /> construction related emissions. The District recommends quantifying construction related <br /> emissions and assessing the projects potential impacts on air quality. <br /> Conditions of Approval - 8- PA-0800005 <br />
The URL can be used to link to this page
Your browser does not support the video tag.