My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0007489 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANN
>
21301
>
2600 - Land Use Program
>
PA-0800348
>
SU0007489 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:05 AM
Creation date
9/6/2019 10:02:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0007489
PE
2622
FACILITY_NAME
PA-0800348
STREET_NUMBER
21301
Direction
N
STREET_NAME
MANN
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01728010
ENTERED_DATE
11/25/2008 12:00:00 AM
SITE_LOCATION
21301 N MANN RD
RECEIVED_DATE
11/24/2008 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MANN\21301\PA-0800348\SU0007489\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br /> Page 12 <br /> COnSUltinZ> Inc. April 6, 2009 <br /> Environmentol• Engineering- Geology Project Number 2009007 <br /> Parcel 1 —Test Hole 2—perched water in hole—NOT Acceptable V <br /> Parcel 2—Test Hole 3 —250 minutes per inch—NOT Acceptable <br /> Parcel 2 —Test Hole 4—62.5 minutes per inch—NOT Acceptable V <br /> Based on the EHD Onsite Wastewater Disposal Standards a standard septic design may <br /> be used for the proposed parcel one. However, based on the percolation rates obtained on the <br /> Proposed parcel two, an engineered septic system will be required. <br /> Discussion of the Septic System Size <br /> Septic System Construction should follow the San Joaquin County On-Site Wastewater <br /> Disposal Standards where applicable. The Engineered system should be designed and submitted <br /> to San Joaquin County, Environmental Health Department for approval. <br /> 7. CONCLUSION <br /> In summary, a satisfactory percolation rate of the soil was achieved in the proposed septic <br /> disposal area for proposed parcel one at the Site. The septic disposal area appears suitable for a <br /> standard septic system. A non-satisfactory percolation rate of the soil was achieved in the <br /> proposed septic disposal area for proposed parcel two at the Site. The septic disposal area <br /> appears to require a engineered septic system. Perched ground water was encountered in one <br /> bo led on the property at 21 feet. The results reported 14.2 mg/l of Total Nitrogen as N <br /> d 1.0 ugIL pb) of DBCP. California MCL for Total Nitrogen is 45 mg1L and for DBCP is <br /> 0.2 ug/l. <br /> 8. LIMITATIONS <br /> This report is applicable only for the project and site studied. Report findings and <br /> JR SQUARED CONSULTING,INC. ENVIRONMENTAL•ENGINEERING•GEOLOGY <br /> 6532 MCNEIL COURT,VALLEY SPRINGS,CA 95252 PHONE(209)772-3841 -FAX(249)740-4303 <br />
The URL can be used to link to this page
Your browser does not support the video tag.