�., ..i <br /> 18 May 2007 <br /> AGE-NC-07-1528 <br /> Page 3 of 5 <br /> 5.0. SOIL DESCRIPTIONS <br /> On 12 April 2007, AGE applied for and received an Onsite Wastewater Treatment System Permit <br /> from the SJCEHD. On 13 April 2007,a 4-inch hang auger was utilized to advance a test hole in the <br /> subject parcel.The test hole was located in an area where the proposed septic system is to be located. <br /> The test hole (TH-2)was advanced to a depth of 68-inches bsg. <br /> The soil was visually described in accordance with the Unified Soil Classification System by a <br /> representative of AGE under the direct supervision of a California Professional Geologist. The soil <br /> sample collected from TH-2 consisted of soils ranging from silty sands to hard pan clays. <br /> Table 1 <br /> SOIL DESCRIPTION TH-2 <br /> Depth Interval (ft bsg) Soil Description Soil Classification <br /> 0-5 dry, brown clay with sand CL <br /> 6.0. PERCOLATION TESTS <br /> On 02 May 2007,one boring was advanced(TH-1)for shallow percolation rate testing.The boring <br /> was advanced using a 4-inch hand auger.Boring TH-I was advanced to a depth of 42-inches(Figure <br /> 2).The borings were located more than 100 feet from the proposed well location and within 100 feet <br /> of the proposed septic system location. <br /> On 02 May 2007, the sides of the boring were scraped and loose material was removed from the <br /> boring. Once the boring was cleared, a 4-inch diameter PVC pipe with perforations on the bottom <br /> and 2 inches of fine gravel were added to the borings. Then the boring was filled with water to a <br /> depth of 12 inches above gravel at 0930. Test hole TH-1 was covered for 24 hours to allow <br /> saturation of the boring. <br /> On 03 May 2007, test hole TH-lwas inspected prior to initiation of the 4-hour percolation test. <br /> Boring TH-1 was found to be completely dry,but intact and in good condition. Six inches of clean <br /> water was added to the boring to initiate the 4-hour percolation test.The 4-hour percolation test was <br /> performed by recording the amount of water remaining in the boring at 30-minute intervals. <br /> Additional water was added to the boring if required to ensure that approximately 6-inches of water <br /> remained. Water level was measured from a fixed reference point on the PVC casing using a solinst <br /> water level meter. Measurements indicated on the Percolation Test Rate form are in decimal feet. <br /> Advanced GeoEnvironmenhl,Inc. <br />