Laserfiche WebLink
3.2 Description of All Past On-Site Potential and/or Known Above and Below Ground <br /> f Sources of Contamination Identified at the Project Site: Past on-site potentials for <br /> contamination are low. The property has been used for agricultural purposes for more than 10 <br /> years. Historically the orchard has been treated with Chloropicrin, Guthon, Penncap and <br /> Paraquat to name a few of the chemicals used. (See permit number 39-03-3900142 for all <br /> pesticides used at the project site, located in Appendix). Historically there have been no <br /> underground storage tanks. The owner has no knowledge of above ground storage of <br /> chemicals on the subject parcel. <br /> 3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence <br /> of buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> There are no storage tanks above ground. There are no above ground fuel tanks on the site. <br /> On-site storm water is contained on -site and dissipates through either percolation or <br /> evaporation. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Past off-site potential <br /> for contamination is low. The subject parcel is located in agricultural community. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified in the Area of the Project Site: Present off- <br /> site <br /> ffsite potential for contamination is low. There is no ow knowledge of below ground sources of <br /> e <br /> contamination in the area of the project site that has or may impact the project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of Each Potential and/or Known Source of Contamination Identified for <br /> any Real and/or Potential Threat to Human Health and the Environment: The depth p to <br /> i . <br /> ground water n this area is approximate) 140 feet. Due to this depth, an pesticides, <br /> � <br /> Y p y p cedes, <br /> insecticides, and fertilizers used on the property in the past or present would have a moderate <br /> r impact to the ground water. <br /> a <br /> � 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers for fuel storage <br /> tanks on this site; thus the potential for contamination is low. As was stated above, any <br /> l : pesticides, insecticides, and fertilizers used on the site do not pose any significant potential for J <br /> C <br /> contamination to the project site, and no mitigation measures are recommended. <br /> 2 <br /> i J c:107991Surface and Subsurface October, 2007 <br /> I <br />