Laserfiche WebLink
7. For each proposed new building, provide the following information on the plans: <br /> a. Description of proposed use <br /> b. Existing and proposed occupancy Groups <br /> c. Type of construction <br /> d. Sprinklers (Yes or No <br /> e. Number of stories <br /> f. Building height <br /> g. Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC <br /> j. Occupant load based on the CPC <br /> 8. The building shall be provided with an automatic fire sprinkler system or separated into <br /> conforming fire areas, on a case by case basis. <br /> 9. If high piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will be required. <br /> 10. Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building <br /> or facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. § 11 B-206.2.1 <br /> 11. At least one accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 12. At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines, which are <br /> otherwise connected by a circulation path. §11 B-206.2.4 <br /> 13. Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project. These parking space(s) shall be located as close as possible to <br /> the primary entrance to the building. <br /> 14. Adequate sanitary facilities shall be provided for each building, per the requirements of Chapter <br /> 4 of the California Plumbing Code. <br /> 15. Pursuant to Section 422.4 of the California Plumbing Code, toilet facilities shall be accessible <br /> to employees at all times, should not be more that 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> 16. This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> requirements of the California Code of Regulations, title 22, Division 2, Chapter 2.7. <br /> k. FIRE PREVENTION BUREAU: The following California Fire Code (CFC) requirements will be <br /> applicable to the proposed project. The following conditions shall be addressed prior to submittal of a <br /> building permit application to the Building Inspection Division. <br /> PA-1700043 (UP, TE) Conditions of Approval 4 <br />