SU0008416 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KOSTER
>
33662
>
2600 - Land Use Program
>
PA-1000179
>
SU0008416 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:29 AM
Creation date
9/6/2019 10:42:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0008416
PE
2690
FACILITY_NAME
PA-1000179
STREET_NUMBER
33662
Direction
S
STREET_NAME
KOSTER
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25516026 27 32
ENTERED_DATE
8/20/2010 12:00:00 AM
SITE_LOCATION
33662 S KOSTER RD
RECEIVED_DATE
8/19/2010 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KOSTER\33662\PA-1000179\SU0008416\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P6.6 Complete Percolation Test Form (including readings)was provided with REHS <br /> verification signature. The rate was correctly calculated using the last reading. See <br /> Appendix for Test Result Form. <br /> TEST HOLE PERCOLATION RATE <br /> 1 (Parcel 1) 19 MIN./IN. <br /> F 2 (Parcel 2) 31 MIN./IN. <br /> 3 (Parcel 3) 18 MIN./IN. <br /> V 4 (Designated Remainder) 19 MIN./IN. <br /> *See Results in Appendix. <br /> ' 6.7 Discussion of any potent ional <br /> roblems predicted and/or the need for an <br /> p <br /> engineered or alternative septic system. In this area,the sails are classified as Capay <br /> Clay and El Solyo Clay loam. Due to this classification and percolation rate, a <br /> non-engineered standard septic would be recommended. <br /> 6.8 Discussion of percolation rates in relation to the type, size and location of future <br /> leach fields needed at the site. Based on the results of theerc 1 <br /> p o atxon rates and sails <br /> profile, it is Dillon & Murphy's opinion that the subject proposed Parcels are suited for <br /> typical on-site sewage disposal systems. The system should be properly designed and <br /> installed according to the current San Joaquin County criteria for standard septic systems. <br /> FBased on the depth to groundwater in the area, and the size of the proposed parcels, <br /> it is our opinion that the installation of any new proposed septic system, if properly installed, <br /> should not adversely affect the quality of groundwater in the area. <br /> 7.0 CONCLUSION SECTION <br /> I <br /> The� <br /> Fi conclusions of this report are based on the information provided regarding proposed <br /> the <br /> development, the use of the subject property, and the site conditions as they existed at the <br /> time we excavated our test hole andperformed the percolation test. It was assumed that the <br /> test holes and percolation test results are representative of the subsurface conditions in the <br /> general area. <br /> Our services were performed, our findings obtained, and our conclusionsro osed <br /> p p <br /> in accordance with generally accepted engineering principles and practices. This <br /> warranty is in lieu of all other warranties either expressed or implied. Test findings and <br /> statements of professional opinion do not constitute a guarantee warranty, expressed or implied. <br /> /� c� oe Murphy <br /> ,U -_ - ;'! R.C.E. 45,277 <br /> 52 <br /> Fl� sal <br /> � l <br /> sTgr crv►� �, <br /> 4 <br />