KLE/NFELOER <br /> V fll9MFropk.NyM1tSONieom. <br /> `- periodically monitored for several parameters including pH, conductivity, and <br /> temperature. Copies of the purge logs are included in Appendix B. Prior to sample <br /> collection, the sample ports were cleaned with a Liquinox solution. <br /> The water samples were collected in laboratory grade sample containers, labeled, <br /> logged on a chain-of-custody, and placed in a cooler with ice prior to transport to the <br /> laboratory by courier under chain-of-custody control. <br /> LABORATORY ANALYSIS <br /> Each of the water samples collected was analyzed for boron, calcium, magnesium, iron, <br /> potassium, sodium, alkalinity, hardness, pH, specific conductance, total dissolved <br /> ` solids, chloride, nitrate, orthophosphate, sulfate and silicon by EPA methods. The <br /> samples were analyzed by California Laboratory Services (CLS) of Rancho Cordova, <br /> California. CLS is certified by the State of California Department of Health Services <br /> (DHS) to perform the requested analysis. <br /> _ FINDINGS <br /> DTW in the wells has been measured and recorded since 1999 (with the exception of <br /> ` DW-2 which was measured back to 2001). The attached Table 1 summarizes these <br /> measurements by Kleinfelder and others. <br /> .. The DTW in DW-1 (215 feet), DW-2 (158 feet), and DOM-1 (161 feet) was consistent <br /> with previous measurements in each of the wells. <br /> The results of the laboratory analyses of the samples collected during the 2011 annual <br /> monitoring event and previous monitoring events at the site are summarized in attached <br /> Table 2. The laboratory analyses of the groundwater samples collected from the wells <br /> (DW-1, DW-2, and DOM-1) showed generally consistent results compared with previous <br /> monitoring events at the site. In addition, the analytical results indicate similar water <br /> quality between the monitoring locations. For details of the analyses conducted and <br /> laboratory quality assurance controls, please refer to the laboratory reports included in <br /> Appendix A. <br /> RECOMMENDATIONS <br /> Kleinfelder recommends that Knife River continue the annual collection of groundwater <br /> ►. elevation data and groundwater samples for laboratory analyses from available wells in <br /> accordance with San Joaquin County requirements. Kleinfelder also recommends <br /> sending a copy of this report to the Central Valley Regional Water Quality Control <br /> Board. <br /> ` 29131.E01/ST012R014 Page 2 of 4 January 17, 2012 <br /> Copyright 2012 Kleinfelder <br /> IV <br />