Laserfiche WebLink
04/07/2003 04:18 2098306837 CITY OF TRACY FIRE PAGE 02le,3 <br /> Prevention Division <br /> 520 N. Tracy Boulevard <br /> Tracy, California 95376 <br /> 209.831.4707 <br /> fax 209-830-6837 <br /> Date: April 7, 2003 <br /> To: Jose Rubianes, San Joaquin Community Development Department <br /> From: Jeffrey J. Mason, Fire PreventionV- � <br /> Re: 11515 W. Larch Rd, Application#PA-0300116 (PA) <br /> The following Uniform Fire Code and City of Tracy Municipal Code requirements will be <br /> applicable and shall be incorporated in the construction plans before submittal to Development <br /> and Engineering Services for a building permit. <br /> ® Fire flow and hydrants will be provided for the proposed project by the use of: <br /> ❑ Appendix IIIA and I11-13 of the California fire Code (Public Water Mains) <br /> ® NFPA 1142 of the National Fire Code <br /> ❑ Fire Sprinkler systems shall be installed according to Article 10 of the California Fire <br /> Code and the appropriate standards and guides adopted in Chapter 35 of the California <br /> Building Code and the California Electric Code. Fire Department Connections shall have <br /> Knox FDC caps installed. <br /> ® Fire Department access roads shall be in accordance with section 902.2 of the California <br /> fire code and the standard adopted by the San Joaquin Fire Chiefs Association <br /> ® ICey Boxes: A Knox box shall be installed according to the Fire Department a instructions. <br /> ® Fire extinguishers shall be installed in accordance with California Fire Code,standard <br /> 10.1 of volume 2 and recommended sizing of the fire Department based on hazard(e). <br /> ® Fire permits may be required prior to occupancy to conduct operations hazardous to life or <br /> property. (C.F.C.105.2.1) (Assembly permit and possible hood and duet permit) <br /> ❑ Mechanical refrigeration systems shall comply with all applicable codes(ammonia, etc.). <br /> ❑ A Hazardous Material Business Plan and/or a Risk Management Plan may be required by <br /> San Joaquin County Office of Emergency Services due to etorage/use of hazardous <br /> materials. Phone' 209 468.3962. <br /> ❑ A technical report to determine the acceptability of technologies, processes,products, <br /> facilities materials and uses attending the design, operation or use of the building or <br /> premises may be required. (Uniform Fire Code Section 103.1.1). <br /> ❑ Other: <br /> 6/fire Pm -h./Plan Check 4 ft"aw/Moster Plan Check/pd <br />