Laserfiche WebLink
k. All new construction and substantial improvements to existing structures in areas of special flood <br /> hazard shall be anchored to prevent flotation, collapse, or lateral movement of the structure resulting <br /> from hydrodynamic and hydrostatic loads, including the effects of buoyancy. All mobile homes shall <br /> meet the anchoring standards of Section 9-1605.10. <br /> I. Unless otherwise specified, construction within areas of special flood hazards shall comply with the <br /> following standards for materials and methods: <br /> (1) All new construction and substantial improvements shall be constructed with materials and utility <br /> equipment resistant to flood damage. <br /> V <br /> (2) All new construction and substantial improvements shall be constructed using methods and <br /> practices°that minimize flood damage. <br /> c�hnstruction and substantial-improvements-shall--be=constr-ueted-with-electric-al;heating;-- <br /> ventilation, plumbing, and air conditioning equipment and other service facilities that are <br /> designed'and/or located so as to prevent water from entering or accumulating within the <br /> components during conditions of flooding. <br /> m. Unless otherwise specified, the following standards of construction relative to elevation and flood <br /> proofing shall'be complied with in areas subject to flooding. All new construction and substantial <br /> improvements of any structure in areas of special flood hazard shall have the lowest floor, including <br /> basement, elevated to at least one foot above the 100-year flood elevation. Upon completion of the <br /> structure, th*Ievation of the lowest flood, including the basement, shall be certified by a registered <br /> civil engineeror licensed land surveyor. Such certification shall be provided to the Floodplain <br /> Administrato�T (Development Title Section 9-1601.11[a]]b]) <br /> n. All new and replacement water supply and sanitary sewage systems shall be designed to minimize <br /> or eliminate infiltration of flood waters into the system and discharge from systems.into flood waters. <br /> (Development Title Section 9-1605.13[a]) <br /> o. Waste disposal systems shall be located to avoid impairment to them or contamination from them <br /> during flooding. (Development Title Section 9-1605.13[b]) <br /> INFORMATIONAL NOTES: <br /> (1) This property is subject to the requirements of the San Joaquin County Mosquito and Vector <br /> Control District(209-9824675)and the California Health and Safety Code for the prevention of <br /> mosquitoes. Best Management Practices guidelines for storm water devices,_ponds, and <br /> wetlandsare available. <br /> (2) All future building permits for projects located within a Special Flood Hazard Area at the time of <br /> permit issuance shall meet the San Joaquin County flood hazard reduction requirements (Title 9, <br /> Chapter 9-1605)and all requirements of the State of California(CCR Title 23)that are in force at <br /> the time of permit issuance. As an example, these requirements may include raising the finish <br /> floor eley.ation one foot above the expected flood level and/or using flood resistant materials. <br /> 3. ENVIRONMENTXL HEALTH DEPARTMENT(Staff Contact: Ted Tasiopoulos, 953-7698) <br /> a. A soil suitabilitylnitrate loading study incorporating proposed staff and customer use shall be <br /> submitted to. <br /> ,Fnvironmental Health indicating that the area is suitable for septic system usage. The <br /> studies must be approved by Environmental Health prior to issuance of building permits <br /> (Development Title Section 9-1105.2[d]). A review fee of$575.00 must be paid at the time of <br /> San Joaquin County PA-10000341Adhikari <br /> Community Developrkient Page 9 <br />