My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012027
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LEHMAN
>
3590
>
2600 - Land Use Program
>
PA-1800266
>
SU0012027
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:36 AM
Creation date
9/6/2019 10:50:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012027
PE
2633
FACILITY_NAME
PA-1800266
STREET_NUMBER
3590
Direction
W
STREET_NAME
LEHMAN
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
25504020
ENTERED_DATE
10/16/2018 12:00:00 AM
SITE_LOCATION
3590 W LEHMAN RD
RECEIVED_DATE
10/18/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\L\LEHMAN\3590\PA-1800266\SU0012027\APPL.PDF \MIGRATIONS\L\LEHMAN\3590\PA-1800266\SU0012027\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Each parking stall shall be an unobstructed rectangle, minimum nine (9) feet wide and twenty <br /> (20) feet long. (Development Title Section 9-1015.5[b]) <br /> 5. All parking stalls and directional arrows must be delineated with paint. (Development Title Section <br /> 9-1015.5[d]) <br /> e. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> 1. Access driveways shall have a width of no less than twenty-five (25)feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty(20)feet wide. (Development Title Section 9-1015.5[h][1]) <br /> 2. The approved site plan shows the access driveway from Lehman Road encroaching on an <br /> adjacent property owned by the Banta Carbona Irrigation district (BCID). As a result, one of the <br /> following options shall be completed prior to issuance of a building permit: <br /> A. A"Notice of Lot Line Adjustment" shall be recorded and deeds transferred prior to issuance <br /> of a building or grading permit. <br /> B. An approved Improvement Plan application for a private right-of-way across the BCID <br /> property shall be required prior to issuance of a building or grading permit. . <br /> C. The driveway shall be entirely located on the project parcel. <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> 1. If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> 2. Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that <br /> such light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> g. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be included <br /> on the Site Plan. All portions of any sign shall be set back a minimum of five (5)feet from any future <br /> right-of-way line, including any corner cut-off(snipe). (Development Title Section 9-1710.2[g]) <br /> h. BUILDING DEPARTMENT REQUIREMENTS: The following California Building Code (CBC) and <br /> San Joaquin County Ordinance requirements will be applicable and shall be incorporated in the <br /> construction plans before submittal to the Building Inspection Division: <br /> 1. A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance withThe 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2. A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> PA-1 800266—Conditions of Approval 2 <br />