Conditions of Approval <br /> SA-92-0068 <br /> Page 4 <br /> (1) The proposed building shall be provided with an <br /> automatic fire sprinkler system or divided into <br /> areas less than 6, 000 square feet by area <br /> separation walls. This does not include the <br /> greenhouses. <br /> (2) Provide restrooms conforming with all disabled <br /> access requirements. (CCR, Title 24) <br /> (3) The floor area of the repair shop (H-4 occupancy) <br /> shall be served by one or more floor drains which <br /> shall drain to an approved grease and oil <br /> separator. The separator shall have prior approval <br /> by the Public Health Services (Environmental Health <br /> Division) before submission to this Division for <br /> permits and meet all the criteria for hazardous <br /> waste generation. <br /> b. A grading plan shall be submitted and approved and a <br /> grading permit issued by the Building Inspection Division <br /> prior to performing any excavation or filling of earth <br /> material: <br /> (1) A grading plan shall contain the information listed <br /> in the UBC, Appendix, Chapter 70 , Section 7006 (1) . <br /> (2) The grading plan shall include complete drainage <br /> details and elevations of the adjacent parcels. <br /> Retaining wall details shall be submitted where <br /> applicable. <br /> (3) Grading in excess of 5, 000 cubic yards shall comply <br /> with Section 7014 for "Engineered Grading <br /> Requirements. " <br /> (4) All recommendations of the soils engineer shall be <br /> incorporated in the grading plans. <br /> (5) All compaction reports must be submitted prior to a <br /> foundation inspection. <br /> (6) All grading permits are subject to approval by the <br /> other departments. <br /> (7) All grading authorized by the permit shall be <br /> approved prior to issuance of any building permits, <br /> or beginning of any construction. <br />