Laserfiche WebLink
SEPTIC SYSTEM CONSTRUCTION <br /> All septic system requirements must be in accordance with the San Joaquin County Environmental Health Sewage Standards. <br /> For gravity systems, the house pad most be raised to permit gravity flow through both septic tanks and into leach field. <br /> The double septic system design shown on this plan must comply with the following:(Sec. 10 Sewage Standards.) MIN.25DEEP <br /> SEEPAGE PITS(TYP.) <br /> Minimum distance from well to seepage pits 150' <br /> Minimum distance from trenches to well 100' <br /> Minimum distance from foundations,driveways and pools 10' <br /> Maximum length of individual leach line 100, <br /> Maximum width of trench 24" <br /> Maximum grade of line 3"per 100' <br /> Preferable grade of line 2"per 100' <br /> Distance between lines 10'edge to edge <br /> Minimum depth of rock below approved perforated pipe 12" <br /> Minimum depth of rock over approved perforated pipe 2" <br /> Maximum depth of trench 42" <br /> Minimum distance between leach line and septic tank 5' LEACHLINES AND TRENCHES <br /> Maximum soil cover over Inch line 24" (TYP.-MIN.10'EDGE TO EDGE) <br /> Minimum soil cover over leach line 6" <br /> During leachfield concoction,the sidewalls and floors of the leachline trenches most be scarified to open smeared soil surfaces possibly <br /> caused from the backhoe excavations. Seepage pits are nomnally scarified by a"cleat"on the outside of the auger flight. All excavations <br /> should be inspected by a representative from San Joaquin County Public Health Services Department Environmental Health Division, <br /> before placement of drain rock. Telephone at least 48-hours in advance of inspection (209) 468-3284. <br /> Leachfield areas cannot be driven or parked over,and no structures can be built over these areas. Final grading of the leachfields most <br /> be such that drainage water from domestic irrigation or rainfall cannot collect and pond over the leachfields.Only grasses and small <br /> shrubs may be planted over the fields,with pees and large shrubs planted at least 15 feet away. The designated replacement area most <br /> remain as such,with no permanent structures built in this area <br /> SEPTIC SYSTEM MAINTENANCE <br /> The septic system installed for the respective residence must consist of a dual leachfield system in accordance with San Joaquin Sewage <br /> Standards,Section 10.1.For the system to have maximum theoretical longevity,the leachfields most be manually switched between DISTRIBUTION <br /> each other on an annual basis.Ibis cam be accomplished with a push-pull"gate"valve,which will be on each of the two effluent lines BOX DISTRIBUTION <br /> Irexiting the secondary septic tank It may be a requvemen[by the Envimnmrnfal Health Department that the valves 6e located within TANK o o PRIMARY <br /> the second compartment of the secondary tank. This second compartment must also have an installed filter. BULL RUN VALVE ES) (OR) o o TANK <br /> The Emma mmental Health Department will require that the tanks be pumped every three years. Therefore,access to the tanks by pumper (IN CHRISTIE BOX) <br /> woks most be maintained Since the septic systems will be installed in fine-grained clay soils,sodium from a water softener may hasten <br /> the clogging mechanisms of this soil type,which may lead to septic system failure. Therefore,water softeners should be avoided or NK <br /> limited in use. Water from domestic irrigation or rainfall must not be allowed to congregate in the leachfietd areas. <br /> By signing below,the homeowner has read and understands the concoction and maintenance procedures,as stated above and agrees <br /> to perform these recommended procedures. This information most be transferred to a buyer upon sate of the applicable residences. <br /> qt,o ESS 0 <br /> SIGNED PRINTED NAME DATE tERR�Q'� yFj�Z4, HOUSE <br /> 2 <br /> DOUBLE SYSTEM LEACHFIELD REQUIREMENTS <br /> IN ACCORDANCE WITH SAN JOAQUIN COUNTY SEWAGE STANDARDS {r Erp. 3-3103 <br /> 'PJCFpRCNN1e����T <br /> Leachline Length(ft.) Size of Primary and No.and Dia.(in.) OF CAUF04 PLAN VIEW <br /> No of Bedrooms Requirements Secondary Septic Tanks of Seepage Pits No.and Length(k)of Leachlines <br /> 3 300 ft 1200+1200 gals 2A2"(160 ft eq.) 2-70 ft 160'+140'=300') TYPICAL DOUBLE SEPTIC SYSTEM DESIGN PLATE <br /> a ago rc soo+lsoo gals 342"(240 ft.eq.) 3-55 ft 240'+165'=405') h� K L E I N F E L D E R <br /> 5 Soo ft 2000+2000 els 3d2'(240fte .)) 3-85ft 240'+255'=495') HEATHER MOOR ESTATES <br /> 6 600 ft 2000+2000 gals 4-42'(320 ft eq.) 4-70 ft 320'+280'=600') UNIT No.2 <br /> (Except for septic tank sizes,all requirements shove pertain to a single leachfield and therefore must be doubled). <br /> GATE PRO 0'1611001E REVISED: SAN JOAOUIN COUNTY,CALIFORNIA <br /> PROJ.10.21-292112 FILEN AME:20110620.FH9 <br /> w.xxxaa,IK.zoo, <br />