Laserfiche WebLink
SEPTICSYSTEM CONSTRUCTION <br /> All septic system requirements must be in accordance with the San Joaquin County Environmental Health Sewage Standards. <br /> For gravity systems, the house pad must be raised to permit gravity flow through both septic tanks and into leach field. <br /> The double septic system design shown on this plan must comply with the following:(Sec. 10 Sewage Standards.) MIN.25'DEEP <br /> SEEPAGE PITS(TYP.) <br /> Minimum distance from well to seepage pits 150' <br /> Minimum distance from trenches to well 100' <br /> Minimum distance from foundations,driveways and pools 10' <br /> Maximum length of individual leach line 100' <br /> Maximum width of trench 24" <br /> Maximum grade of line 3"per 100' <br /> Preferable grade of line Y'per 100' <br /> Distance between lines 10'edge to edge <br /> Minimum depth of rock below approved perforated pipe 12" <br /> Minimum depth of rock over approved perforated pipe T' <br /> Maximum depth of trench 42" LEACHLINES AND TRENCHES <br /> Minimum distance between leach line and septic tank 5' (TVP.-MIN.10'EDGE TO EDGE) <br /> Maximum soil cover over leach line 24" <br /> Minimum soil cover over leach line 6" <br /> During leachfield construction,the sidewalk and floors of the leachline trenches most be scarified to open smeared and surfaces possibly <br /> caused from the backhoe excavations. Seepage pits are normally scarified by a"cleat"on the outside of the auger flight. All excavations <br /> should be inspected by a representative from San Joaquin County Public Health Services Department Environmental Health Division, <br /> before placement of drain rock. Telephone at least 48-hours in advance of inspection (209) 468-3284. <br /> Leachfield areas cannot be driven or parked over,and no structures can be built over these areas. Final grading of the leachfields most <br /> be such that drainage water from domestic irrigation or rainfall cannot collect and pond over the leachfields.Only grasses and small <br /> shrubs may be planted over the fields,with trees and large shrubs planted at least 15 feet away. The designated replacement area most <br /> remain as such,with no peananent structures built in this arca- <br /> SEPTIC <br /> reaSEPTIC SYSTEM MAINTENANCE <br /> The septic system installed for the respective residence most consist of a dual leachfield system in accordance with San Joaquin Sewage <br /> Standards,Section 10.1.For the system to have maximum theoretical longevity,the leachfields most be manually switched between <br /> each other on an annual basis.This can be accomplished with a push-pull"gate"valve,which will be on each of the two effluent lines BOX(TYP)ION C <br /> exiting the secondary septic tank It may be a requirement by the Environmental Health Department that the valves be located within SECONDARY SEPTIC TANK 4TANK RIMARY <br /> the second compartment of the secondary tank. This second compartment must also have an installed filter. BULL RUN VALVE o (SEE ATTACHED NOTES) (OR) <br /> The Environmemal Health Department will require that the tanks be pumped every three years. Therefore,access m the tanks by pumper (IN CHRISTIE BOX) <br /> trucks must be maintained Since the septic systems will be installed in fine-grained clay soils,sodium from a water softener may hasten <br /> the clogging mechanisms of this soil type,which may lead to septic system failure. Therefore,water softeners should be avoided or c PRIMARY SEPTIC TANK <br /> limited in use. Water from domestic irrigation or rainfall must not be allowed to congregate in the leachfield areas. <br /> By signing below,the homeowner has read and understands the construction and maintenance procedures,as stated above and agrees <br /> to perform these recommended procedures. This information most be transferred to a buyer upon sale of the applicable residences. <br /> QAOFESS <br /> SIGNED PRINTED NAME DATE ty'e4' tF11g A HOUSE <br /> gg 2l' 2 <br /> DOUBLE SYSTEM LEACHFIELD REQUIREMENTS 4- ' <br /> IN ACCORDANCE WITH SAN JOAQUIN COUNTY SEWAGE STANDARDS p Exp..' <br /> r0.7.51-03 <br /> ,J'�, CFORCNWt�y xQ! <br /> Leachline Length(ft.) Size of Primary and No.and Dia.(in.) ArF OF CAUfOQ PLAN VIEW <br /> No.of Bedrooms Requirements Secondary Septic Tanks of Seepage Pits No.and Length(ft.)of Leachlines <br /> 3 300 ft 1200+1200 gals 2-42"(160 ft eq.) 2-70 ft 160'+140'=300') TYPICAL DOUBLE SEPTIC SYSTEM DESIGN PUTS <br /> 4 400 ft 1600+1600 gals 3-42'(240 ft.eq.) 3-55 ft 240 +165'=405' <br /> 5 Soo ft 2000+2000 gals 3-42"(240 ft eq.) 3-85h 240'+255'=495' h� K L E I N F E L D E R HEATHER MOOR ESTATES <br /> 6 600 ft 2000+2000 gals 4-42"(320 ft eq.) 4-70 ft 320'+280'=600' UNIT No.2 �1 <br /> (Except for septic tank sizes,all requirements above pertain to a single leachfield and therefore must be doubled). DATE PROpuCEO:IDl16l2ogt oATE REVISED. SAN JOAQUIN COUNTY,CALIFORNIA <br /> PROD.N0.:2q-2921-02 FILENAME:2m1tp620.FH9 <br /> xa, <br />