My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008326_SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4274
>
2600 - Land Use Program
>
PA-1000135
>
SU0008326_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:52:19 PM
Creation date
9/8/2019 12:59:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0008326
PE
2632
FACILITY_NAME
PA-1000135
STREET_NUMBER
4274
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
APN
17917236 37
ENTERED_DATE
6/28/2010 12:00:00 AM
SITE_LOCATION
4274 S HWY 99
RECEIVED_DATE
6/24/2010 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4274\PA-1000135\SU0008326\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Escotto and indicates a percolation rate for the holes based on the <br /> final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. A deep <br /> percolation test hole has a depth greater than 3.5 up to 25 feet; a satisfactory <br /> percolation rate for a deep test is 30 min/in or less. For the Site to utilize a standard <br /> k septic system, one percolation test (either a shallow or deep test) must demonstrate a <br />` satisfactory percolation rate within the proposed septic system disposal field. <br /> Only a shallow percolation test was performed. Details and results of the percolation <br /> test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> Test Hole 1, <br /> 10/20/2010 3.21 15.6 4 hr. 4inchsattisb= <br /> Shallow TestNote, A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per <br /> percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the sewage disposal area of the Site have demonstrated a satisfactory <br /> percolation rate for the use of a standard septic system in accordance with the - <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and seepage pits should follow the San <br /> Joaquin County.On-Site Wastewater Disposal Standards(2003) where applicable. <br /> LOGE1025 Page 6 <br /> I <br /> t <br />