Laserfiche WebLink
P . 03 <br /> Oct-08-03 02 : 50P <br /> i <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> c rbdr Sa �nd.nry <br /> ?' z nanny K. Iteran,H.F:.H.s. P <br /> I :< <br /> ��• )irrctur <br /> 304 haSl Weber Avenue, Third 1IOOr Carl norgman.R.RE..E11.t-S1.. <br /> Mike Huggin ,R.E.H.S., <br /> AI Ulrcn,R.F.HS. Stockton, California 9$202-2708 tUuglasWWilsoo,R.E.n <br /> 5.S. <br /> . <br /> r ,.n„va"'grTelephone: (209) 468-3420 <br /> Mugarc[Lagnno,Lrie ACault6H.S. <br /> 1nigan A9un4Arr Fax: (209)464-0)38 Ruben McClellan, <br /> Mark Oarcdlus.R.LH.S..E.H.S. <br /> October 8, 2003 <br /> TO: San Joaquin County <br /> Community Development Department <br /> FROM: San Joaquin County <br /> Environmental Health Departmcnt <br /> CONTACT PERSON: Robin Trindade, Senior R.D.I., R.L.H.S. <br /> PHONE,NUMBER: (209)468-3445 <br /> RE: PA-03-52 (SA), Attention: Jennifer Jolley <br /> 4310 South State Route 99 Fast Frontage Road <br /> The San Joaquin County Development Title Requirements listed below have been identified as <br /> pertinent to this project. Other requirements may also apply. These requirements cannot be <br /> modified <br /> A. Environmental Health Department requires a soil suitability study incorporating proposed <br /> number of employees and customer use,indicating that the area is suitable for septic tank <br /> usage. This must be performed prior to issuance of a building permit(s)(San Joaquin County <br /> Dcvelopn,ent'fitle, Section 9-1105.2(d)). A review fee of S 186.00 must be paid at time of <br /> submittal to Environmental Health Department. <br /> The sewage disposal system shall comply with the on site sewage standards of San Joaquin <br /> County prior to approval. A percolation test that meets absorption rates of the manual of <br /> septic tank practice or E.P.A. Design Manual for onsite wastewater treatment and disposal <br /> System is required for each parcel. A permit fee of$93.00 per percolation hole is required. <br /> B. State on revised site plans the maximum number of proposed employees and customers the <br /> sewage disposal system is being designed for and that the leach field area will be barricaded <br /> so it cannot be driven over, parked on,or used as a storage area. This leach field area must <br /> be used for that specific purpose only,and it cannot contain any underground utility lines <br /> (San Joaquin County Development Title, Section 9-1110.4(c)(5)). <br /> In addition, the revised site plan shall show the existing septic system, the designed septic <br /> system, and the 100% replacement for both septic systems <br /> Page 1 of 2 <br />