My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006235
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4320
>
2600 - Land Use Program
>
PA-0500006
>
SU0006235
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:58:58 PM
Creation date
9/8/2019 12:59:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006235
PE
2656
FACILITY_NAME
PA-0500006
STREET_NUMBER
4320
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
APN
17917234
ENTERED_DATE
8/31/2006 12:00:00 AM
SITE_LOCATION
4320 S HWY 99
RECEIVED_DATE
8/31/2006 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4320\PA-0500006\SU0006235\APPL.PDF \MIGRATIONS\N\HWY 99\4320\PA-0500006\SU0006235\CDD OK.PDF \MIGRATIONS\N\HWY 99\4320\PA-0500006\SU0006235\EH COND.PDF \MIGRATIONS\N\HWY 99\4320\PA-0500006\SU0006235\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 15, 2004 <br /> NOA Project Number: E04152A <br /> Page 2 <br /> and Mobile Home No. 1. The test indicated that the percolation rate is probably greater than 42 <br /> minutes per inch at three hours. The test was not performed in accordance with the EHD <br /> standards due to lack of available project time to schedule an EHD inspection. The percolation <br /> test was performed to provide our office some idea of the soil type and the percolation rate. The <br /> soil type was found to be lean to fat dark gray clay, slightly moist from recent rains. <br /> Our recommendations are that there is room for the motel septic system and 100% replacement <br /> area as shown on the attached sheets. The existing septic systems should be repaired as needed <br /> under permit with the EHD. There appears to be some repair area available adjacent to the two <br /> mobile homes and restaurant for their septic systems. This letter and the system drawings should <br /> be submitted to the EHD for review. The EHD will require a plan review fee of$186. If the <br /> review is expedited,the fee will increase. <br /> It is possible that any properly designed and constructed septic system may require repairs within <br /> years following construction. In no way can we offer a guarantee or warranty that the septic <br /> system will not require repair in the future. The purpose for the 100%replacement area is to <br /> allow enough room for repair should it be required in the future. <br /> Our professional services were performed, our findings obtained, and our recommendations <br /> proposed in accordance with generally accepted engineering principles and practices. This <br /> warranty is in lieu of all other warranties either expressed or implied. Test findings and <br /> statements of professional opinion do not constitute a guarantee or warranty, expressed or <br /> implied. If there are any questions please contact our office. <br /> Best Regards, <br /> NEIL O. ANDERSON &ASSOC., INC. <br /> cc No. 2151 Oy � <br /> CERTIFIED <br /> ENGINEERING <br /> David Welch, M.Sc., Env. Div. Manager `h GEOLOGIST �Q <br /> CEG-2151, CHG-653, GP-1049 �f <br /> OF C_A�\FO <br /> G et S. H. Hubbart, General Manager <br /> Registered Geotechnical Engineer 2588 <br /> PpFESS/p <br /> 5.H- <br /> aft: Septic System Design Sheets 2e No.2ssa , z <br /> Septic System Permit Copies 3 c� E b-3B-07 ' m <br /> xp. <br /> s'QTDT ErHN���aF <br />
The URL can be used to link to this page
Your browser does not support the video tag.