(6) Parking spaces-will be required to accommodate persons with disability in compliance <br /> with Chapter 11 B ofthe California Building Code.These parking space(s)shall be located <br /> as close as possible to the primary entrance to the building. Note,an additional accessible <br /> parking space will be required at the rear parking area adjacent to the new Fellowship <br /> Hall. <br /> (7) Pursuant to Table 4-3-of the California Plumbing Code, toilet facilities shat[be accessible <br /> to employees at all times, should not be more that 500 feet from where employees are <br /> regularly employed and accessible by not more than one flight of stairs. The plans shall <br /> indicate the location of the toilet facilities and the travel distance from-work areas. <br /> (8) The proposed Classroom/Choir Room (Building 5) will require a property line fire wall, <br /> because of its proximity to the property line. <br /> I. CALIFORNIA FIRE CODE: The following California Fire Code (CFC) requirements will be <br /> applicable to the proposed project. The following conditions shall be addressed prior to <br /> submittal of a building permit application to the Building Inspection Division. <br /> (1) The Fire-Prevention Division has reviewed this application and there does not appear to <br /> be any major problems associated with the proposed project as submitted. A complete <br /> review at building permit submittal will require compliance with applicable codes and <br /> ordinances. <br /> (2) CFC, Section 503 Fire Apparatus Access Roads -Shall be provided as required by this <br /> section. 503.1.2-A secondary access may be required. <br /> (3) CFC, Section 906 Portable Fire Extinguishers — Provide portable fire extinguishers as <br /> required by this section. <br /> (4) CFC, Section 506 Key Box -A Knox® Box shall be installed according to the local fire <br /> department's instructions. Make application for the key box at the fire district having <br /> jurisdiction of this project. If there is an electronically controlled access gate at this site a <br /> Knox®key switch will also be required. <br /> (5) CFC, Section 105 Permits: Operational Permit(s)may be required prior to-occupancy. <br /> 2. DEPARTMENT OF PUBLIC WORKS (Staff Contact Alex Chetley, (209) 468-3000, see memo <br /> dated April 15, 2016) <br /> 3. ENVIRONMENTAL HEALTH DEPARTMENT(Staff Contact:Michael€ssette Jeffrey Wong,(2) <br /> 468 3443(209)468-0335, see memo dated-Apri r3 March 15, 2111 8) <br /> 4. SAN JOAQUIN COUNCIL OF GOVERNMENTS (Staff Contact: Laurel Boyd, (209) 235-0600, <br /> see memo dated April 8, 2916 March 9, 2018) <br /> NOTES AND INFORMATION ONLY <br /> See Central Valley Regional Water Quality Control Board letter dated A^�" 'n r '.'^10 April 12. 2018. <br /> See Federal Emergency Management Agency letter dated A^•".- ' March 26. 2018. <br /> See Pacific Gas and Electric Company letter dated March 12, 2108. <br />