Laserfiche WebLink
for each structure or building, showing compliance with The 2016 California Building, Mechanical, <br />Plumbing, Electrical, Energy, California Green Building Standards, and Fire Codes as may be <br />applicable. Plans for the different buildings or structures may be combined into a single set of <br />construction documents. <br />(2) A grading permit will be required for this project. Submit plans and grading calculations, including <br />a statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br />Professional. The grading plan shall show the existing grade and finished grade in contour <br />intervals of sufficient clarity to indicate the nature and extent of the work and show in detail that it <br />complies with the requirements of the code. The plans shall show the existing grade on adjoining <br />properties in sufficient detail to identify how grade changes will conform to the requirements of the <br />code. <br />(3) The required plans must be complete at the time of submittal for a building permit. Plans must <br />address building design and construction, fire and life safety requirements, accessibility and show <br />compliance with the current California codes and San Joaquin County ordinances. A complete <br />set of plans must include fire sprinkler plans, truss design submittals, metal building shop <br />drawings, structural plans and calculations, plumbing, electrical and mechanical drawings and <br />energy report. <br />(4) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 for <br />grading. All recommendations of the Soils Report shall be incorporated into the construction <br />drawings. <br />(5) For each proposed new building, provide the following information on the plans: <br />a. Description of proposed use <br />b. Existing and proposed occupancy Groups <br />c. Type of construction <br />d. Sprinklers (Yes or No <br />e. Number of stories <br />f. Building height <br />g. Allowable floor area <br />h. Proposed floor area <br />i. Occupant load based on the CBC <br />j. Occupant load based on the CPC <br />(6) The building shall be provided with an automatic fire sprinkler system as per the 2016 California <br />Fire Code. <br />(7) Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br />provided within the site from accessible parking spaces and accessible passenger loading zones; <br />public streets and sidewalks; and public transportation stops to the accessible building or facility <br />entrance they serve. Where more than one route is provided, all routes must be accessible. §11 B- <br />206.2.1 <br />PA -1800232 —Conditions of Approval 2 <br />